Marine Cables | |||
MariTox Marine Flame Retardant Medium Voltage Cables | MariTox Marine Flame Retardant Power & Control Cables | MariFlex Marine Fire Resistant Power & Control Cables | other |
Marine Cable
P30 RFOU-HCF / TFOU-HCF 6/10(12) kV
Applications :
Marine cables are fire resistant, flame retardant, low smoke and halogen free, used for emergency control,
power and lighting systems that need to be operational during a 1100℃ hydrocarbon fire.
Standards :
IEC 60092-354
IEC 60092-360
IEC 60332-1
IEC 60331-21
IEC 60332-3-22
IEC 60754-1,2
IEC 61034-1,2
NEK 606
Construction :
Conductors : Circular tinned annealed stranded copper to IEC 60228 class 2.
Conductor Screen : Semi conducting material.
Insulation : Halogen-free EPR. XLPE can be offered as an option.
Insulation Screen : Semi conducting material and tinned copper wire braid.
Bedding : Halogen free compound.
Armour : Tinned copper wire braid.
Outer Sheath1 : Halogen free thermosetting compound, SHF2, coloured red.
HC-fire protection : Extruded thermoplastic fire protection compound.
Taping : Lapped glass fibre tape.
Outer Sheath2 : Flame retardant halogen-free thermoplastic compound, SHF1, coloured red.
Optional :
P31 RFOU-HCF / TFOU-HCF 8.7/15kV
P32 RFOU-HCF / TFOU-HCF 12/20(24) kV
P33 RFOU-HCF / TFOU-HCF 18/30(36) kV
Electrical Characteristics :
-
Nominal Cross Section Area mm² 70 95 120 150 185 240 300 Nominal Conductor Diameter mm 10.3 12.2 13.8 15.1 17.0 19.6 21.9 Maximum DC Resistant@20℃ Ω/km 0.27 0.195 0.154 0.126 0.1 0.0762 0.0607 Continuous Current Rating@45℃1 Core A 242 293 339 389 444 522 601 Continuous Current Rating@45℃3 Core A 169 205 237 272 311 365 421 Short Circuit Current 1s A 10020 13590 17170 21460 26470 34340 42930 Operating Voltage KV 6/10 6/10 6/10 6/10 6/10 6/10 6/10
Ambient Temperature Correction Factors :
-
Ambient Temperature Correction Factors 35 40 45 50 55 60 65 70 75 80 Rating Factor 1.1 1.05 1.0 0.94 0.88 0.82 0.74 0.67 0.58 0.47
Mechanical and Thermal Properties :
Bending Radius : 25×OD (during installation); 12×OD (fixed installed).
Temperature Range : -20℃ ~ +90℃.
Dimensions and Weight :
Construction No. of cores×Cross section (mm²) |
Nominal Insulation Thickness mm |
Nominal Diameter Over Bedding mm |
Nominal Diameter Over Sheath1 mm |
Nominal Overall Diameter mm |
Nominal Weight kg/km |
---|---|---|---|---|---|
1×70 | 3.4 | 23.5 | 30.0 | 62.0 | 5220 |
1×95 | 3.4 | 25.5 | 32.0 | 64.5 | 5900 |
1×120 | 3.4 | 27.5 | 34.0 | 66.5 | 6340 |
1×150 | 3.4 | 28.5 | 35.0 | 67.5 | 6670 |
1×185 | 3.4 | 30.5 | 36.5 | 69.0 | 7320 |
1×240 | 3.4 | 33.0 | 39.0 | 72.0 | 8250 |
1×300 | 3.4 | 35.0 | 41.5 | 74.5 | 9280 |
3×50 | 3.4 | 47.0 | 55.0 | 89.0 | 10970 |
3×95 | 3.4 | 54.0 | 62.5 | 97.0 | 14230 |
3×150 | 3.4 | 60.0 | 70.5 | 106.0 | 17400 |