Marine Cables
MariTox Marine Flame Retardant Medium Voltage Cables MariTox Marine Flame Retardant Power & Control Cables MariFlex Marine Fire Resistant Power & Control Cables other

Marine Cable

P7 or P7/P14 BFOU 6/10kV

Applications :

Standards :

IEC 60092-354

IEC 60092-360

IEC 60332-1

IEC 60331-21

IEC 60332-3-22

IEC 60754-1,2

IEC 61034-1,2

NEK 606

BS 6883&BS7917 Offshore & Marine cablesBS 6883&BS7917 Offshore & Marine cables

Construction :

Conductors : Circular tinned annealed stranded compacted copper to IEC 60228 class 2.

Conductor Screen : Semi conducting material.

Insulation : Mica tape + Halogen free EPR.

Insulation Screen : Semi conducting material and tinned copper wire braid.

Bedding : Halogen free compound.

Armour : Tinned copper wire braid.

Outer Sheath : Halogen free thermosetting compound, SHF2 (for TYPE P7), or halogen free mud resistant

thermosetting compound, SHF MUD (for TYPE P7/P14), coloured red.

Electrical Characteristics :

 

Ambient Temperature Correction Factors :

Mechanical and Thermal Properties :

Bending Radius :15×OD (during installation); 9×OD (fixed installed).

Temperature Range : -20℃ ~ +90℃.

Dimensions and Weight :

Construction No. of cores×Cross section
mm²
Nominal Insulation Thickness
mm
Nominal Sheath Thickness
mm
Nominal Overall Diameter
mm
Nominal Weight
kg/km
Inner Outer
1×16 3.4 1.0 1.6 25.6 990
1×25 3.4 1.0 1.7 27.1 1150
1×35 3.4 1.0 1.7 28.5 1320
1×50 3.4 1.0 1.8 29.9 1500
1×70 3.4 1.0 1.8 31.9 1810
1×95 3.4 1.0 1.9 34.0 2160
1×120 3.4 1.2 2.0 36.1 2610
1×150 3.4 1.2 2.1 38.1 2990
1×185 3.4 1.2 2.2 39.9 3440
1×240 3.4 1.2 2.3 43.1 4180
1×300 3.4 1.2 2.4 45.9 4930
1×400 3.4 1.4 2.5 49.0 5900
1×500 3.4 1.4 2.6 52.5 7070
1×630 3.4 1.4 2.8 57.0 8690
3×16 3.4 1.4 2.4 50.2 3780
3×25 3.4 1.4 2.6 53.2 4380
3×35 3.4 1.4 2.7 56.4 5040
3×50 3.4 1.4 2.8 59.3 5740
3×70 3.4 1.6 2.9 63.7 6900
3×95 3.4 1.6 3.1 68.4 8270
3×120 3.4 1.6 3.2 72.1 9470
3×150 3.4 1.6 3.4 76.0 10800
3×185 3.4 1.8 3.5 80.8 12370
3×240 3.4 1.8 3.8 88.2 15040
3×300 3.4 2.0 3.9 94.0 17450