IEC60092 Offshore & Marine Cables
MariTox Marine Flame Retardant Medium Voltage Cables MariTox Marine Flame Retardant Power & Control Cables MariFlex Marine Fire Resistant Power & Control Cables other

Water Blocked

S16 BFOU-HCF(c) 250 V

Applications

Marine cables are partially water blocked, fire resistant, flame retardant, low smoke and halogen free, used for

emergency instrumentation, communication, control and alarm systems that need to be operational during a

1100˚C hydrocarbon fire.

Standards

IEC 60092-376

IEC 60092-360

IEC 60332-1

IEC 60332-3-22

IEC 60754-1,2

IEC 61034-1,2

NEK 606

IEC 60331-21

VG 95218 part 29

IEC60092 Offshore & Marine Cables

Construction

Conductors: Circular tinned stranded copper wire to IEC 60228 class 2.

Insulation: Mica tape + Halogen free EPR compound.

Twinning: Colour coded cores twisted together.

Collective Shielding: Pairs/triples are layed up and collectively screened by copper backed polyester tape in

contact with a stranded tinned copper drain wire. Pairs/triples are numbered with numbered tape or by numbers

printed directly on the insulated conductors.

Filler: Water blocking fillers, if required.

Bedding: Halogen free compound, PETP wrapping tape will be applied over the bedding, if required.

Armour: Tinned copper wire braid, PETP wrapping tape will be applied over the braiding, if required.

Water Blocking Elements: Water blocking tape and strings for providing longitudinal water tightness.

Inner Sheath: Halogen free thermosetting compound, SHF2.

HC-fire protection: Extruded thermoplastic fire protection compound.

Taping: Lapped glass fibre tape.

Outer Sheath 1: Flame retardant halogen-free thermoplastic compound, type SHF1, coloured grey (blue for

intrinsically safe).

Outer Sheath 2: Polyurethane for providing transversal water tightness, PE is optional,but can not meet low

smoke standard.

Electrical Characteristics

Mechanical and Thermal Properties

Bending Radius : 20×OD (during installation); 12×OD (fixed installed).

Temperature Range : -20℃ ~ +90℃.

Dimensions and Weight

Construction No. of elements×No. of cores in element×Cross section
mm²
Nominal Insulation Thickness
mm
Nominal Diameter Over Bedding
mm
Nominal Diameter Over Inner Sheath
mm
Nominal Overall Diameter
mm
Nominal Weight kg/km
2×2×1.5 0.7 13 16.4 46.5±2 2520
4×2×1.5 0.7 15 19.9 48.5±2 2783
8×2×1.5 0.7 20.5 25.3 55.0±2 3749
12×2×1.5 0.7 23.5 29.6 59.0±2 4368