IEC60092 Offshore & Marine Cables
MariTox Marine Flame Retardant Medium Voltage Cables MariTox Marine Flame Retardant Power & Control Cables MariFlex Marine Fire Resistant Power & Control Cables other

UKOOA TYPE GM / TYPE GP 150/250V Fire Resistant

Application

Marine cables are designed for fixed installation for control and lighting in both and safe areas, emergency and

critical offshore applications where cable protection is required.

Standards

BS 6883/BS 7917/UKOOA

IEC 60331-21

IEC 60332-3-22 CAT. A

IEC 60332-1

IEC 60754-1 & IEC 60754-2

IEC 61034-1 & IEC 61034-2

Construction

Conductors:Stranded class 2 or flexible class 5 tinned annealed copper conductors to BS 6360/IEC 60228.

Fire Protection:Mica glass tape

Insulation:EPR complying with BS7655 GP4 

Drain Wire:Tinned copper drain wire 

Individual Screen:Aluminium mylar tape screen

Bedding:EVA - SW4 compound complying with BS 7655 

Armour : Galvanised steel wire braid to BS 6883 

Outer Sheath :EVA - SW4 compound complying with BS 7655(TYPE GM: Blue; TYPE GP: Grey).

Dimensions and Weight

Construction
No. of cores×Cross section
Nominal Insulation Thickness
Nominal Thickness of Inner Sheath 
Nominal Thickness of Outer Sheath 
Mominal Overall Diameter
Approx. Weight
mm² mm mm mm mm kg/km
3×2×0.75 0.8 1.2 1.4 18.6 580
7×2×0.75 0.8 1.4 1.6 23.2 915
12×2×0.75 0.8 1.6 1.8 29.7 1420
20×2×0.75 0.8 2.1 2.7 40.1 2905
3×3×0.75 0.8 1.3 1.5 20.4 700
7×3×0.75 0.8 1.5 1.7 26.6 1180
12×3×0.75 0.8 1.9 2.2 38.5 2550
1×4×0.75 0.8 1.2 1.3 14.6 360
1×2×1.0 0.8 1.0 1.2 13.0 295
1×3×1.0 0.8 1.0 1.2 13.6 330
1×4×1.0 0.8 1.0 1.3 15.9 380
3×2×1.5 0.8 1.3 1.4 21.6 732
7×2×1.5 0.8 1.4 1.6 27.8 1242
12×2×1.5 0.8 1.7 1.9 36.4 2039
3×3×1.5 0.8 1.3 1.5 24.5 780
7×3×1.5 0.8 1.5 1.7 32.1 1409
12×3×1.5 0.8 1.8 2.0 43.9 2301