Medium Voltage Cables
Medium Voltage Cables to BS 6622 Medium Voltage Cables to IEC 60502 Medium Voltage Cables to VDE 0276

Medium Voltage Cables to VDE 0276

Three Core 18/30KV (Um=36KV) N2XSEY
NA2XSEY
Dimensional Data

Nom. Cross- Section Area

Approx. Conductor Diameter

Nom. Insulation Thickness

Copper Tape Screen
Area (0.1mm)

Copper Wire Screen Area

Approx. Insulation Diameter

Nom. Sheath Thickness

Approx. Overall Diameter

Approx. Weight

 

CU

 

AL

mm²

mm

mm

mm²

mm²

mm

mm

mm

kg/km

kg/km

50

8.25

8.0

9.9

16

25.9

2.0

68

5800

4900

70

9.90

8.0

10.5

16

27.5

2.0

71

6800

5500

95

11.7

8.0

11.2

16

29.3

2.1

75

8000

6100

120

13.1

8.0

12.0

16

30.7

2.1

79

9000

6700

150

14.3

8.0

12.5

25

31.9

2.2

81

10100

7300

185

16.3

8.0

13.2

25

33.9

2.2

86

11800

8300

240

18.7

8.0

14.3

25

36.3

2.3

91

14000

9400

300

20.9

8.0

15.2

25

38.5

2.4

97

16500

10700

400

23.7

8.0

16.2

35

41.3

2.5

103

19700

12300

Three Core 18/30KV (Um=36KV) Galvanized Steel Tape Armoured Cables N2XSEYBY
NA2XSEYBY
Dimensional Data

Nom. Cross- Section Area

 

Approx. Conductor Diameter

 

Nom. Insulation Thickness

Copper
Tape Screen Area (0.1mm)

Copper Wire Screen Area

 

Approx. Insulation Diameter

 

Nom. Armour Thickness

 

Nom. Sheath Thickness

 

Approx. Overall Diameter

 

Approx. Weight

 

CU

 

AL

mm²

mm

mm

mm²

mm²

mm

mm

mm

mm

kg/km

kg/km

50

8.25

8.0

9.9

16

25.9

0.5

3.2

72

7300

6400

70

9.90

8.0

10.5

16

27.5

0.5

3.3

75

8400

7100

95

11.7

8.0

11.2

16

29.3

0.5

3.5

80

9700

7900

120

13.1

8.0

12.0

16

30.7

0.8

3.6

84

11700

9400

150

14.3

8.0

12.5

25

31.9

0.8

3.7

87

12900

10100

185

16.3

8.0

13.2

25

33.9

0.8

3.9

92

14800

11300

240

18.7

8.0

14.3

25

36.3

0.8

4.0

98

17300

12600

300

20.9

8.0

15.2

25

38.5

0.8

4.2

103

20000

14100

400

23.7

8.0

16.2

35

41.3

0.8

4.4

110

23500

16000

Three Core 18/30KV (Um=36KV) Galvanized Flat Steel Wire+Steel Tape Armoured Cables
N2XSEYFGbY NA2XSEYFGbY
Dimensional Data

Nom. Cross- Section Area

 

Approx. Conductor Diameter

 

Nom. Insulation Thickness

Copper
Tape Screen Area (0.1mm)

Copper Wire Screen Area

 

Approx. Insulation Diameter

 

Nom. Armour Thickness

 

Nom. Sheath Thickness

 

Approx. Overall Diameter

 

Approx. Weight

 

CU

 

AL

mm²

mm

mm

mm²

mm²

mm

mm

mm

mm

kg/km

kg/km

50

8.25

8.0

9.9

16

25.9

0.8

3.2

72

7500

6600

70

9.90

8.0

10.5

16

27.5

0.8

3.3

76

8600

7300

95

11.7

8.0

11.2

16

29.3

0.8

3.5

80

10000

8100

120

13.1

8.0

12.0

16

30.7

0.8

3.6

83

11200

8900

150

14.3

8.0

12.5

25

31.9

0.8

3.7

86

12400

9500

185

16.3

8.0

13.2

25

33.9

0.8

3.9

91

14100

10600

240

18.7

8.0

14.3

25

36.3

0.8

4.0

97

16600

11900

300

20.9

8.0

15.2

25

38.5

0.8

4.2

102

19200

13400

400

23.7

8.0

16.2

35

41.3

0.8

4.4

109

22700

15300

 

Electrical Data

 

Nom. Cross- Section Area

 

D C
Resistance CU / AL

 

A C
Resistance CU / AL

 

Short Circuit Rating of Conductor CU / AL
1 sec

 

Capacitance

 

Charging Current

Short Circuit Rating of Copper Wire Screen
Per Core 1 sec

Short Circuit Rating of Copper Tape Screen
Per Core 1 sec

 

Reactance

 

Inductance

mm²

µΩ/m

µΩ/m

kA

pF/m

mA/m

kA

kA

µΩ/m

nH/m

50

387/641

494/822

6.8/4.4

142

0.85

1.96

1.45

134

430

70

268/443

343/568

9.8/6.3

159

0.95

1.96

1.54

127

400

95

193/320

248/410

13.3/8.5

175

1.05

1.96

1.64

121

390

120

153/253

196/325

17.2/11.0

189

1.13

1.96

1.75

117

370

150

124/206

159/265

21.2/13.5

201

1.21

3.06

1.83

113

360

185

99/164

128/211

26.6/17.0

217

1.3

3.06

1.93

109

350

240

75/125

98/161

34.9/22.3

237

1.42

3.06

2.09

104

330

300

60/100

80/130

43.8/28.0

258

1.55

3.06

2.21

101

320

400

47/78

64/102

57.3/36.6

282

1.69

4.29

2.37

96

290