Mining Cable | |||
Type W | Type G | Type G-GC | more |
Mining Cable
Paper Insulated 11/11KV
Applications
These cables are used as HV feeder cables in fixed conditions.
Standards
AS/NZS 1972:2006
AS/NZS 1125
AS/NZS 3808
Construction
Conductors: Sector shaped stranded copper conductor.
Insulation: Paper tape.
Filling: Jute fillers.
Insulation: Paper tape belt insulation.
Inner Sheath: Lead sheath.
Bedding: PVC sheath.
Armour: Galvanized steel wire armour.
Outer Sheath: PVC sheathto AS/NZS 1026.
Dimensions and Weight
Nominal Conductor Area | Minimum Insulation Thickness | Nominal Lead Sheath Thickness | Armour Wire Diameter | Nominal Sheath Thickness | Nominal Overall Diameter | Nominal Weight | |
---|---|---|---|---|---|---|---|
Between Conductors | Between Conductors and Lead Sheath | ||||||
mm² | mm | mm | mm | mm | mm | mm | kg/100m |
25 | 5.6 | 5.4 | 1.8 | 2.5 | 2.4 | 47.9 | 630 |
35 | 5.6 | 5.4 | 1.8 | 2.5 | 2.5 | 50.3 | 695 |
50 | 5.6 | 5.4 | 1.8 | 2.5 | 2.5 | 50.1 | 725 |
70 | 5.6 | 5.4 | 1.9 | 2.5 | 2.6 | 53.5 | 855 |
95 | 5.6 | 5.4 | 2.0 | 2.5 | 2.6 | 57.2 | 1000 |
120 | 5.6 | 5.4 | 2.0 | 2.5 | 2.7 | 60.1 | 1120 |
150 | 5.6 | 5.4 | 2.1 | 2.5 | 2.8 | 63.0 | 1260 |
185 | 5.6 | 5.4 | 2.3 | 3.15 | 2.9 | 68.0 | 1540 |
240 | 5.6 | 5.4 | 2.4 | 3.15 | 3.0 | 73.1 | 1820 |
300 | 5.6 | 5.4 | 2.6 | 3.15 | 3.2 | 77.9 | 2120 |
400 | 5.6 | 5.4 | 2.7 | 3.15 | 3.4 | 83.5 | 2500 |