Power Cables | ||||||||||||
|
Power Cables
5-8kV XLPE Insulated PVC Sheathed Unarmoured Power Cable 100/133% Insulation Levels
100% Insulation Levels (single conductor)
Conductor | Insulation
thickness
mm |
Sheath
thickness
mm |
Overall
Dia. approx. mm |
AC Test
voltage
kV / 5 min |
Cable
weight approx. kg / km |
||
---|---|---|---|---|---|---|---|
Size
AWG or MCM |
Construction
No. / mm |
Outside Dia. mm |
|||||
6 4 2 1 1/0 |
7/1.56 7/1.96 7/2.47 19/1.69 C.C. |
4.67 5.88 7.42 8.43 8.53 |
2.92 2.92 2.92 2.92 2.92 |
1.52 1.52 1.52 1.52 1.52 |
17.6 18.8 20.3 21.4 21.4 |
18 18 18 18 18 |
433 534 687 796 897 |
2/0 3/0 4/0 250 300 |
C.C. C.C. C.C. C.C. C.C. |
9.55 10.74 12.07 13.21 14.48 |
2.92 2.92 2.92 2.92 2.92 |
2.03 2.03 2.03 2.03 2.03 |
23.6 24.8 26.1 27.2 28.5 |
18 18 18 18 18 |
1112 1306 1546 1758 2021 |
350 400 500 100 750 1000 |
C.C. C.C. C.C. C.C. C.C. C.C. |
15.65 16.74 18.69 20.65 23.06 26.92 |
2.92 2.92 2.92 2.92 2.92 2.92 |
2.03 2.03 2.03 2.03 2.03 2.03 |
29.7 30.8 32.7 34.7 37.1 41.1 |
18 18 18 18 18 18 |
2282 2549 3058 3604 4369 5651 |
100% Insulation Levels (Three conductor)
Conductor | Insulation
thickness
mm |
Sheath
thickness
mm |
Overall
Dia. approx. mm |
AC Test
voltage
kV / 5 min |
Cable
weight approx. kg / km |
||
---|---|---|---|---|---|---|---|
Size
AWG or MCM |
Construction
No. / mm |
Outside Dia. mm |
|||||
6 4 2 1 1/0 |
7/1.56 7/1.96 7/2.47 19/1.69 C.C. |
4.67 5.88 7.42 8.43 8.53 |
2.92 2.92 2.92 2.92 2.92 |
2.03 2.03 2.03 2.79 2.79 |
35.0 37.6 40.9 44.8 45.0 |
18 18 18 18 18 |
1400 1734 2224 2760 3065 |
2/0 3/0 4/0 250 300 |
C.C. C.C. C.C. C.C. C.C. |
9.55 10.74 12.07 13.21 14.48 |
2.92 2.92 2.92 2.92 2.92 |
2.79 2.79 2.79 2.79 2.79 |
47.2 49.7 52.6 55.1 57.8 |
18 18 18 18 18 |
3565 4179 4937 5622 6447 |
350 400 |
C.C. C.C. |
15.65 16.74 |
2.92 2.92 |
2.79 2.79 |
60.4 62.7 |
18 18 |
7278 8129 |
133% Insulation Levels (single conductor)
Conductor | Insulation
thickness
mm |
Sheath
thickness
mm |
Overall
Dia. approx. mm |
AC Test
voltage
kV / 5 min |
Cable
weight approx. kg / km |
||
---|---|---|---|---|---|---|---|
Size
AWG or MCM |
Construction
No. / mm |
Outside Dia. mm |
|||||
6 4 2 1 1/0 |
7/1.56 7/1.96 7/2.47 19/1.69 C.C. |
4.67 5.88 7.42 8.43 8.53 |
3.56 3.56 3.56 3.56 3.56 |
1.52 1.52 1.52 2.03 2.03 |
19.0 20.2 21.7 23.9 24.0 |
22 22 22 22 22 |
479 583 739 914 1015 |
2/0 3/0 4/0 250 300 |
C.C. C.C. C.C. C.C. C.C. |
9.55 10.74 12.07 13.21 14.48 |
3.56 3.56 3.56 3.56 3.56 |
2.03 2.03 2.03 2.03 2.03 |
25.0 26.2 27.5 28.6 29.9 |
22 22 22 22 22 |
1173 1369 1611 1826 2092 |
350 400 500 100 750 1000 |
C.C. C.C. C.C. C.C. C.C. C.C. |
15.65 16.74 18.69 20.65 23.06 26.92 |
3.56 3.56 3.56 3.56 3.56 3.56 |
2.03 2.03 2.03 2.03 2.03 2.79 |
31.1 32.2 34.1 36.1 38.5 44.1 |
22 22 22 22 22 22 |
2354 2624 3137 3687 4457 5922 |
133% Insulation Levels (Three conductor)
Conductor | Insulation thickness mm |
Sheath
thickness
mm |
Overall
Dia. approx. mm |
AC Test
voltage
kV / 5 min |
Cable
weight approx. kg / km |
||
---|---|---|---|---|---|---|---|
Size
AWG or MCM |
Construction
No. / mm |
Outside Dia. mm |
|||||
6 4 2 1 1/0 |
7/1.56 7/1.96 7/2.47 19/1.69 C.C. |
4.67 5.88 7.42 8.43 8.53 |
3.56 3.56 3.56 3.56 3.56 |
2.03 2.03 2.79 2.79 2.79 |
38.0 40.6 45.6 47.8 48.0 |
22 22 22 22 22 |
1568 1910 2589 2964 3269 |
2/0 3/0 4/0 250 300 |
C.C. C.C. C.C. C.C. C.C. |
9.55 10.74 12.07 13.21 14.48 |
3.56 3.56 3.56 3.56 3.56 |
2.79 2.79 2.79 2.79 2.79 |
50.2 52.8 55.7 58.1 60.9 |
22 22 22 22 22 |
3775 4415 5177 5869 6716 |
350 400 |
C.C. C.C. |
15.65 16.74 |
3.56 3.56 |
2.79 2.79 |
63.4 65.7 |
22 22 |
7540 8398 |