Power Cables | ||||||||||||
|
Power Cables
8.7/15(17.5)kV XLPE Insulated PVC Sheathed Unarmoured Power Cable
Single Core (Unarmoured )
Conductor | Conductor screen ( mm ) |
Insulation thickness ( mm ) |
Insulation screen ( mm ) |
Copper screen tape ( mm ) |
Sheath thickness ( mm ) |
Overall diameter approx. ( mm ) |
Cable weight approx. ( kg/km ) |
Insulation resistance at 15.6∑C (Min.) ( Mohm/km) |
||
---|---|---|---|---|---|---|---|---|---|---|
Size
(mm) |
Shape | Outside diameter ( mm ) |
||||||||
25 35 50 70 95 |
C.C. C.C. C.C. C.C. C.C. |
5.91 6.95 8.05 9.67 11.39 |
0.8 0.8 0.8 0.8 0.8 |
4.5 4.5 4.5 4.5 4.5 |
0.8 0.8 0.8 0.8 0.8 |
0.1 0.1 0.1 0.1 0.1 |
1.7 1.7 1.8 1.8 1.9 |
24.0 25.1 26.3 28.0 29.9 |
769 898 1050 1305 1614 |
2100 1900 1700 1500 1400 |
120 150 185 240 300 |
C.C. C.C. C.C. C.C. C.C. |
12.83 14.24 15.98 18.32 20.65 |
0.8 0.8 0.8 0.8 0.8 |
4.5 4.5 4.5 4.5 4.5 |
0.8 1.0 1.0 1.0 1.0 |
0.1 0.1 0.1 0.1 0.1 |
1.9 2.0 2.0 2.1 2.2 |
31.5 33.4 35.3 37.8 40.3 |
1900 2237 2650 3285 3950 |
1300 1200 1100 1000 900 |
400 500 630 |
C.C. C.C. C.C. |
23.33 26.34 30.50 |
0.8 0.8 0.8 |
4.5 4.5 4.5 |
1.0 1.0 1.0 |
0.1 0.1 0.1 |
2.3 2.4 2.5 |
43.2 46.7 51.1 |
4846 5917 7448 |
850 750 700 |
3 Core (Unarmoured )
Conductor | Conductor screen ( mm ) |
Insulation thickness ( mm ) |
Insulation screen ( mm ) |
Copper screen tape ( mm ) |
Sheath thickness ( mm ) |
Overall diameter approx. ( mm ) |
Cable weight approx. ( kg/km ) |
Insulation resistance at 15.6∑C (Min.) ( Mohm/km) |
||
---|---|---|---|---|---|---|---|---|---|---|
Size
(mm) |
Shape | Outside diameter ( mm ) |
||||||||
25 35 50 70 85 |
C.C. C.C. C.C. C.C. C.C. |
5.91 6.95 8.05 9.67 11.39 |
0.8 0.8 0.8 0.8 0.8 |
4.5 4.5 4.5 4.5 4.5 |
0.8 0.8 0.8 0.8 0.8 |
0.1 0.1 0.1 0.1 0.1 |
2.5 2.6 2.7 2.8 2.9 |
49.9 52.3 54.9 58.7 62.6 |
2582 3001 3496 4323 5318 |
2100 1900 1700 1500 1400 |
120 150 185 240 300 400 |
C.C. C.C. C.C. C.C. C.C. C.C. |
12.33 14.24 15.98 18.32 20.65 23.33 |
0.8 0.8 0.8 0.8 0.8 0.8 |
4.5 4.5 4.5 4.5 4.5 4.5 |
0.8 1.0 1.0 1.0 1.0 1.0 |
0.1 0.1 0.1 0.1 0.1 0.1 |
3.0 3.2 3.3 3.4 3.6 3.8 |
66.0 70.2 74.2 79.7 85.1 91.3 |
6237 7329 8657 10687 12817 15669 |
1300 1200 1100 1000 900 850 |
3 Core (Steel Wire Armoured)
Conductor | Insulation thickness ( mm ) |
Copper screen tape ( mm ) |
Inner sheath thickness ( mm ) |
Armour wire diameter ( mm ) |
Outer sheath thickness ( mm ) |
Overall diameter approx. ( mm ) |
Cable weight approx. ( kg/km ) |
Insulation resistance at 15.6∑C (Min.) ( Mohm/km) |
||
---|---|---|---|---|---|---|---|---|---|---|
Size
(mm) |
Shape | Outside diameter ( mm ) |
||||||||
25 35 50 70 95 |
C.C. C.C. C.C. C.C. C.C. |
5.91 6.95 8.05 9.67 11.39 |
4.5 4.5 4.5 4.5 4.5 |
0.1 0.1 0.1 0.1 0.1 |
1.4 1.4 1.4 1.6 1.6 |
2.5 2.5 2.5 2.5 2.5 |
2.5 2.6 2.7 2.8 2.9 |
53 56 59 63 67 |
4640 6200 6010 7010 8160 |
2100 1900 1700 1500 1400 |
120 150 185 240 300 |
C.C. C.C. C.C. C.C. C.C. |
12.33 14.24 15.98 18.32 20.65 |
4.5 4.5 4.5 4.5 4.5 |
0.1 0.1 0.1 0.1 0.1 |
1.6 1.6 1.6 1.8 1.8 |
2.5 2.5 2.5 3.15 3.15 |
3.1 3.2 3.3 3.5 3.6 |
71 74 78 85 90 |
9260 10600 12000 15300 17700 |
1300 1200 1100 1000 900 |
3 Core (Steel Tape Armoured)
Conductor | Insulation thickness ( mm ) |
Copper screen tape ( mm ) |
Inner sheath thickness ( mm ) |
Armour tape diameter ( mm ) |
Outer sheath thickness ( mm ) |
Overall diameter approx. ( mm ) |
Cable weight approx. ( kg/km ) |
Insulation resistance at 15.6∑C (Min.) ( Mohm/km) |
||
---|---|---|---|---|---|---|---|---|---|---|
Size
(mm) |
Shape | Outside diameter ( mm ) |
||||||||
25 35 50 70 95 |
C.C. C.C. C.C. C.C. C.C. |
5.91 6.95 8.05 9.67 11.39 |
4.5 4.5 4.5 4.5 4.5 |
0.1 0.1 0.1 0.1 0.1 |
1.4 1.4 1.4 1.6 1.6 |
0.5 0.5 0.5 0.5 0.5 |
2.5 2.6 2.7 2.8 2.9 |
52 55 57 61 65 |
3960 4420 5150 6110 7290 |
2100 1900 1700 1500 1400 |
120 150 185 240 300 |
C.C. C.C. C.C. C.C. C.C. |
12.33 14.24 15.98 18.32 20.65 |
4.5 4.5 4.5 4.5 4.5 |
0.1 0.1 0.1 0.1 0.1 |
1.6 1.6 1.6 1.8 1.8 |
0.5 0.5 0.5 0.5 0.5 |
3.1 3.2 3.3 3.5 3.6 |
69 72 76 83 88 |
8140 9220 10700 13400 15300 |
1300 1200 1100 1000 900 |
* C.C.: Stranded and compacted circular. |