Railway Cables | ||||||||||
|
3.6/6KV Single Core Dual Wall Traction Cables
Application
Single core power and control cable designed for protected, fixed installation inside and outside railway vehicles
for connecting fi xed and moving parts in direct current and alternating voltage technology, especially converter
technology
Standards
BS 6853 -1a
DIN 5510-1 1-4
NFF 16-101 F0
Construction
Conductors
Circular Class 5 stranded plain or tinned copper to BS EN 60228: 2005 / BS 6360.
Insulation1
Electron beam crosslinkable thin wall LSZH compound.
Insulation2
Electron beam crosslinkable thin wall LSZH compound.
Screen(optional)
Copper wire screen (for screened and sheathed cables).
Outer Sheath(optional)
Electron beam crosslinkable LSZH compound. (for screened and sheathed cables).
Electrical Characteristics at 20℃
Nominal Conductor Cross Section | mm² | 1.5 | 2.5 | 4.0 | 6.0 | 10 | 16 | 25 | 35 | 50 |
---|---|---|---|---|---|---|---|---|---|---|
Maximum Conductor Resistance | Ω/km | 13.7 | 8.21 | 5.09 | 3.39 | 1.95 | 1.24 | 0.795 | 0.565 | 0.393 |
Voltage Rating | KV | 3.6/6 |
Nominal Conductor Cross Section | mm² | 70 | 95 | 120 | 150 | 185 | 240 | 300 | 400 |
---|---|---|---|---|---|---|---|---|---|
Maximum Conductor Resistance | Ω/km | 0.277 | 0.21 | 0.164 | 0.132 | 0.108 | 0.0817 | 0.654 | 0.0495 |
Voltage Rating | KV | 3.6/6 |
Mechanical and Thermal Properties
Minimum Bending Radius:3×OD (OD<12mm); 4×OD (OD>12mm)
Temperature Range:-40℃ to +120℃
Dimensions And Weight
FRA-DW-6SU (Usheathed)
Cable Code | No. of cores& Nominal
Conductor Cross Sectional Area No.×mm² |
Nominal
Diameter of Strands No/mm |
Nominal
Insulation Thickness mm |
Nominal
Overall Diameter mm |
Nominal
Weight kg/km |
---|---|---|---|---|---|
FRA-DW-6SU-1G1.5 | 1×1.5 | 30/0.25 | 1.4 | 4.4 | 20 |
FRA-DW-6SU-1G2.5 | 1×2.5 | 50/0.25 | 1.5 | 4.9 | 50 |
FRA-DW-6SU-1G4 | 1×4.0 | 56/0.30 | 1.6 | 5.7 | 60 |
FRA-DW-6SU-1G6 | 1×6.0 | 84/0.30 | 1.7 | 6.3 | 90 |
FRA-DW-6SU-1G10 | 1×10.0 | 80/0.40 | 1.8 | 7.5 | 140 |
FRA-DW-6SU-1G16 | 1×16.0 | 126/0.40 | 2.1 | 9.4 | 210 |
FRA-DW-6SU-1G25 | 1×25.0 | 196/0.40 | 2.2 | 10.9 | 300 |
FRA-DW-6SU-1G35 | 1×35.0 | 276/0.40 | 2.4 | 12.5 | 410 |
FRA-DW-6SU-1G50 | 1×50.0 | 396/0.40 | 2.6 | 14.5 | 580 |
FRA-DW-6SU-1G70 | 1×70.0 | 360/0.50 | 2.6 | 16.5 | 770 |
FRA-DW-6SU-1G95 | 1×95.0 | 475/0.50 | 2.8 | 18.3 | 1000 |
FRA-DW-6SU-1G120 | 1×120.0 | 608/0.50 | 2.9 | 20.6 | 1260 |
FRA-DW-6SU-1G150 | 1×150.0 | 756/0.50 | 3.1 | 22.9 | 1610 |
FRA-DW-6SU-1G185 | 1×185.0 | 925/0.50 | 3.3 | 24.8 | 1920 |
FRA-DW-6SU-1G240 | 1×240.0 | 1221/0.50 | 3.4 | 27.8 | 2470 |
FRA-DW-6SU-1G300 | 1×300.0 | 1525/0.50 | 3.6 | 30.8 | 3000 |
FRA-DW-6SU-1G400 | 1×400.0 | 2013/0.50 | 3.7 | 36.5 | 4220 |
FRA-DW-6S-OS (Screened & Sheathed)
Cable Code | No. of cores& Nominal
Conductor Cross Sectional Area No.×mm² |
Nominal
Diameter of Strands No/mm |
Nominal
Insulation Thickness mm |
Nominal
Overall Diameter mm |
Nominal
Weight kg/km |
---|---|---|---|---|---|
FRA-DW-6S-OS-1G1.5 | 1×1.5 | 30/0.25 | 1.4 | 6.6 | 72 |
FRA-DW-6S-OS-1G2.5 | 1×2.5 | 50/0.25 | 1.5 | 7.2 | 89 |
FRA-DW-6S-OS-1G4 | 1×4.0 | 56/0.30 | 1.6 | 8.2 | 120 |
FRA-DW-6S-OS-1G6 | 1×6.0 | 84/0.30 | 1.7 | 9.1 | 150 |
FRA-DW-6S-OS-1G10 | 1×10.0 | 80/0.40 | 1.8 | 10.4 | 220 |
FRA-DW-6S-OS-1G16 | 1×16.0 | 126/0.40 | 2.1 | 12.4 | 330 |
FRA-DW-6S-OS-1G25 | 1×25.0 | 196/0.40 | 2.2 | 14.3 | 390 |
FRA-DW-6S-OS-1G35 | 1×35.0 | 276/0.40 | 2.4 | 15.7 | 550 |
FRA-DW-6S-OS-1G50 | 1×50.0 | 396/0.40 | 2.6 | 17.7 | 740 |
FRA-DW-6S-OS-1G70 | 1×70.0 | 360/0.50 | 2.6 | 20.1 | 970 |
FRA-DW-6S-OS-1G95 | 1×95.0 | 475/0.50 | 2.8 | 22.0 | 1240 |
FRA-DW-6S-OS-1G120 | 1×120.0 | 608/0.50 | 2.9 | 24.7 | 1510 |
FRA-DW-6S-OS-1G150 | 1×150.0 | 756/0.50 | 3.1 | 27.1 | 1900 |
FRA-DW-6S-OS-1G185 | 1×185.0 | 925/0.50 | 3.3 | 29.1 | 2220 |
FRA-DW-6S-OS-1G240 | 1×240.0 | 1221/0.50 | 3.4 | 32.3 | 2830 |