Railway Cables | ||||||
|
FRA 213 URM SW4
Applications :
-
These cables are designed for flexible installations, inside and outside railway rolling stock.
Standards :
-
DIN 5510-2
Construction :
-
Inner conductor:Plain copper.
Insulation:Crosslink PE(PEX).
Outer conductor:Silver plated copper braid.
Sheath:LSZH Elastomer.
Electrical Characteristics at 20 °C :
Impedance | Ω | 50+/-2 |
---|---|---|
Nominal Capacitance | pF/m | 101 |
Minimum Insulation Resistance | MΩ.km | 100000 |
Inner Conductor Resistance | MΩ/km | 5.74 |
Outer Conductor Resistance | MΩ/km | 3.7 |
Attenuation | ||
@10MHz | dB/100m | 2 |
@50MHz | dB/100m | 4 |
@100MHz | dB/100m | 6 |
@150MHz | dB/100m | 8 |
@200MHz | dB/100m | 9 |
@300MHz | dB/100m | 12 |
@400MHz | dB/100m | 14 |
@450MHz | dB/100m | 15 |
@500MHz | dB/100m | 16 |
@600MHz | dB/100m | 18 |
@800MHz | dB/100m | 22 |
@850MHz | dB/100m | 23 |
@900MHz | dB/100m | 24 |
@950MHz | dB/100m | 25 |
@1000MHz | dB/100m | 26 |
@1800MHz | dB/100m | 40 |
@1900MHz | dB/100m | 41 |
@2000MHz | dB/100m | 43 |
Velocity of propagation | % | 66 |
Mechanical and Thermal Properties :
-
MinimumBending Radius:50mm (static)
-
TemperatureRange:-40℃~+105℃
Dimensions and Weight :
Conductor Construction No/mm | NominalInner Conductor Diameter mm | NominalOuter Conductor Diameter mm | NominalOverall Diameter mm | NominalWeight |
---|---|---|---|---|
7/0.75 | 2.25 | 8.15 | 10.3 | 161 |