Railway Cables
Railway Signalling Cable Railway Points Heating Cable

GKW-RW/S EMC 300/500V Thin Wall Screened Multicore

Applications :

Multi core power and control cable designed for protected, fixed installation inside and outside railway vehicles

for connecting fixed and moving parts in direct current and alternating voltage technology,especially converter

technology.

Standards :

EN45545-2

BS 6853 -1a

DIN 5510-1 1-4

NFF 16-101 F0

Construction :

GKW-RW/S EMC 300/500V Thin Wall Screened MulticoreGKW-RW/S EMC 300/500V Thin Wall Screened Multicore

Conductors : Circular Class 5 stranded tinned copper to IEC60228/VDE 0295.

Insulation : Electron beam crosslinkable LSZH compound.

Screen : Copper wire screen.

Sheath : Electron beam crosslinkable LSZH compound.

Electrical Characteristics at 20 °C :

  • Nominal Conductor Cross Section mm² 0.5 0.75 1 1.5
    Maximum Conductor Resistance Ω/km 40.1 26.7 20.0 13.7
    Voltage Rating KV 0.3/0.5

Mechanical and Thermal Properties :

Minimum Bending Radius : 4xOD (Static);

                                           6xOD (Flexing).

Temperature Range : -60℃ ~+120℃ (Static);

                                  -40℃ ~+90℃ (Flexing).

Short Circuit Temperature : +280℃.

Dimensions and Weight :

No. of cores& Nominal
Conductor Cross
Sectional Area
No.×mm²
Number and Nominal Diameter of Strands
No./mm
Nominal Insulation Thickness
mm
Nominal Overall
Diameter
mm
Nominal Weight
kg/km
2×0.5 16/0.20 0.18 4.8 31
3×0.5 16/0.20 0.18 5.0 43
4×0.5 16/0.20 0.18 5.4 50
5×0.5 16/0.20 0.18 6.1 58
6×0.5 16/0.20 0.18 6.5 77
10×0.5 16/0.20 0.18 7.7 111
12×0.5 16/0.20 0.18 8.1 128
14×0.5 16/0.20 0.18 8.6 140
27×0.5 16/0.20 0.18 11.1 238
2×2×0.5 16/0.20 0.18 7.1 89
3×2×0.5 16/0.20 0.18 7.5 103
4×2×0.5 16/0.20 0.18 8.2 130
2×0.75 24/0.20 0.18 5.3 46
3×0.75 24/0.20 0.18 5.6 55
4×0.75 24/0.20 0.18 6.2 63
6×0.75 24/0.20 0.18 7.4 105
7×0.75 24/0.20 0.18 7.7 119
8×0.75 24/0.20 0.18 8.3 137
12×0.75 24/0.20 0.18 9.3 168
16×0.75 24/0.20 0.18 9.8 187
2×2×0.75 24/0.20 0.18 8.0 100
2×1.0 32/0.20 0.18 5.9 63
3×1.0 32/0.20 0.18 6.2 75
4×1.0 32/0.20 0.18 6.8 89
5×1.0 32/0.20 0.18 7.3 108
12×1.0 32/0.20 0.18 10.0 209
2×2×1.0 32/0.20 0.18 8.9 116
2×1.5 30/0.25 0.22 6.7 80
3×1.5 30/0.25 0.22 7.1 98
4×1.5 30/0.25 0.22 7.6 118
5×1.5 30/0.25 0.22 8.3 144
6×1.5 30/0.25 0.22 9.1 170
12×1.5 30/0.25 0.22 11.7 285
NF C32-070-2.1(C2)
IEC 60332-1/EN 50265-2-1
NF C32-070-2.2(C1)
IEC 60332-3/EN50266
IEC 60754-1/NF C20-454
EN 50267-2-1
IEC 61034/NFC20-902
EN 50268/NF C32-073
EN 50267-2-2/NF C32-074
IEC 60754-2/NF C20-453