Railway Cables
Railway Signalling & Control Cables Railway Telecom Cables Railway Power & Control Cables FIRERAIL Traction Cables

 

NSGAFOU Cables

Application

The cables are designed for use in switch cabinets, wiring of devices, trains and buses as well as in dry rooms.

Standards

DIN VDE 0250-602

Construction

NSGAFOU Cables

Conductors

Flexible tinned copper to IEC 60228 class 5.

Insulation

EPR type 3G13.

Outer sheath

PCP type 5GM3.

Electrical Characteristics at 20℃

Nominal Conductor Cross Section mm² 1.5 2.5 4.0 6.0 10 16 25 35
Conductor Resistance Ω/km 13.7 8.21 5.09 3.39 1.95 1.24 0.795 0.565
Current Rating A 31 41 58 75 103 145 194 240
Voltage Rating KV 1.8/3

 

Nominal Conductor Cross Section mm² 50 70 95 120 150 185 240
Conductor Resistance Ω/km 0.393 0.277 0.21 0.164 0.132 0.109 0.0817
Current Rating A 301 372 456 528 607 639 821
Voltage Rating KV 1.8/3

Mechanical and Thermal Properties

Minimum Bending Radius: 4×OD

Temperature Range:-25℃ to +80℃ (during operation);

                                -10℃ to +60℃ (during installation)

Dimensions And Weight

Cable Code No. of cores& Nominal Conductor Cross
Sectional Area
No.×mm²
No. & Nominal Diameter of
Strands
No/mm
Nominal Insulation
Thickness
mm
Nominal Overall
Diameter
mm
Nominal Weight
kg/km
RF602-NSGAFOU-1G1.5 1×1.5 30/0.25 1.3 6.5 59
RF602-NSGAFOU-1G2.5 1×2.5 50/0.25 1.3 6.8 74
RF602-NSGAFOU-1G4 1×4.0 56/0.3 1.3 7.7 94
RF602-NSGAFOU-1G6 1×6.0 84/0.3 1.3 8.3 118
RF602-NSGAFOU-1G10 1×10.0 80/0.4 1.5 9.2 163
RF602-NSGAFOU-1G16 1×16.0 126/0.4 1.5 10.1 220
RF602-NSGAFOU-1G25 1×25.0 196/0.40 1.8 12.5 336
RF602-NSGAFOU-1G35 1×35.0 276/0.40 1.8 14.0 470
RF602-NSGAFOU-1G50 1×50.0 396/0.40 1.8 15.5 581
RF602-NSGAFOU-1G70 1×70.0 360/0.50 1.8 17.0 772
RF602-NSGAFOU-1G95 1×95.0 475/0.50 2.2 19.5 1030
RF602-NSGAFOU-1G120 1×120.0 608/0.50 2.2 21.2 1280
RF602-NSGAFOU-1G150 1×150.0 756/0.50 2.2 23.5 1650
RF602-NSGAFOU-1G185 1×185.0 925/0.50 2.4 25.6 2050
RF602-NSGAFOU-1G240 1×240.0 1221/0.50 2.6 27.3 2590