Robotics |
|||||||||
|
Robotics
Extra Flex 39-40-41-42 39-41 PVC-PUR 40-42 PETP-PUR
Types | Number | sections of pairs | (mm2) |
---|---|---|---|
39-40 | … x 2 x 0.14 | … x 2 x 0.25 | …x 2 x 0.34 |
41-42 | … x 2 x 0.50 | … x 2 x 0.75 | …x 2 x 1.0 |
APPLICATION :
Data Transmission. Dynamic applications Robotics.
TECHNICAL CHARACTERISTICS :
Service Voltage :
300 V
Test Voltage :
1500 V
Insulation Resistance :
20 Mohm x km (at 20oC) for 39-40100 Mohm x km (at 20oC) for 41-42
Capacitance :
abt.120 nF/km at 20oC abt. 100 nF/km at 20oC
Temperature :
service from -10oC to +80oCstorage from -30oC to + 80oC
Conductor Stranding :
extra-flexible class 6 acc. Standards VDE 0295 - IEC 228 - CEI 20-29
Primary Insulation :
Special PVC compound (39-41) according IEC - VDE -CEIpolyester terephtalate PETP (40-42)
Conductors Identification :
colour code acc. DIN 47100.Other identification on request.
EMC shield :
tinned copper braid on total - covering >/= 85%-
Taping :
special tape
Jacket :
polyurethane PUR abrasion-free. Colour gr. RAL 7001
Min. Bending Radius :
10 x external cable diam. (39-41)8 x external cable diam (40-42)
Translation Speed :
180 m/min.
Max. Acceleration :
7 m/s2
Reference Standards :
VDE 0472-804 B - IEC 332.1 - CEI 20-35for flame resistanceVDE 0472-803-B for ASTM2 oil resistanceCNOMO
E.03.40.150 N - NFT 46-013 for resistance to industrial oilsVDE 0472-815 halogen-free version