Robotics |
|||||||||
|
Robotics
Extra Flex F2-F3 F2 PVC-PVC F3 PETP-PUR
Type | Code | Formation | Ext.Diam mm | CU-weight kg/km |
---|---|---|---|---|
F2 | F2CJ12RXC | 3x(2x0.18)+6x0.8 | 9.5 | 83 |
F2 | F2CJ16RXC | 5x(2x0.18)+6x0.8 | 10.6 | 93 |
F3 | F3CJ12RXC | 3x(2x0.18)+6x0.8 | 8.6 | 81 |
F3 | F3CJ16RXC | 5x(2x0.18)+6x0.8 | 9.7 | 91 |
APPLICATION :
Supply of Fanuc brushless motors, Dynamic applications.
TECHNICAL CHARACTERISTICS :
Service Voltage :
300V
Test Voltage :
1500V
Insulation Resistance :
>/= 100 Mohm x km (at 20oC)
Capacitance :
abt. 100 pF/m at 20oC (cond. / cond.) abt. 150 pF/m (cond. / shield)
Temperature :
service from 0oC to +80oC, storage from -20oC to +80oC
Conductor Stranding :
flexible class 5 or 6 acc. Standards VDE 0295 - IEC 228 - CEI 20-29, tinned copper
Primary Insulation :
PETP polyester terephtalate
Conductors Identification :
3 x (2 x 0.18)mm2: (WHT-RD) + (WHT-BLK) + (RD-BLK) 5 x (2 x 0.18)mm2: as above +(WHT-GRN)+(GRN-BLK)6 x 0.8mm2: RD-RD-RD-BLK-BLK-BLK
Taping :
special tape
EMC Shield :
tinned copper braid covering >/= 85%
Jacket :
special PVC compound for type F2 polyurethane PUR abrasion-free for F3 colour black RAL 9005
Min. Bending Radius :
15 x ext. cable diameter for type F2 10 x ext. cable diameter for type F3 colour black RAL 9005
Translation Speed :
120 m/min. for type F2. 180 m/min. for type F3
Max. Acceleration :
4 m/s2 for type F2 7m/s2 for type F3
Reference Standards :
VDE 0472-804 C - IEC 332.3A - CEI 20-22 II for flame resistance for F2 type VDE 0472-804 B - IEC 332.1 - CEI
20-35 for flame resistance for F3 type VDE 0472-803-B ASTM2 oil resistance CNOMO E.03.40.150N - NFT 46-013
for resistance to industrial oils for F3