Robotics

Extra Flex 10-42 Extra Flex S/H/R/F Extra Flex Flat/Armour

Robotics

Extra Flex F4 XLPE-PVC

Code Formation Ext.Diam mm CU-weight kg/km
F4A8PXC 8x2x0.09 6.3 31
F4A10PXC 10x2x0.09 6.9 36
F4A25PXC 25x2x0.09 10.4 73

APPLICATION :

Supply of Fanuc system signals.

TECHNICAL CHARACTERISTICS :

Service Voltage :

300V

Test Voltage :

1500V

Insulation Resistance :

>/= 3000 Mohm x km (at 20oC)

Capacitance :

abt. 60 pF/m at 20oC (contd. / cond.) abt. 100 pF/m at 20oC (cond. / shield)

Temperature :

service from -10oC to +80oC, storage from -40oC to + 80oC

Conductor Stranding :

extra-flexible class 6 acc. Standards VDE 0295 - IEC 228 - CEI 20-29

Primary Insulation :

XLPE cross-linked polythylene

Conductors Identification :

colour code acc. DIN 47100 or other code

EMC Shield :

tinned copper braid covering >/= 85%

Taping :

special tape

Jacket :

special PVC compound colour black RAL 9005

Reference Standards :

VDE 0472-804 B - IEC 332.1 - CEI 20-35 for flame resistance VDE 0472-803-B ASTM2 oil resistance CNOMO

E.03.40.150N - NFT 46-013 for resistance to industrial oils.