Telephone Cables
Outdoor Telephone Cables Indoor Telephone Cables Indoor/Outdoor Telephone Cables Special Telephone Cables

Ordering Information

 PE Insulated Air Core/Jelly Filled Star Quad Railway Signalling Cables (RF 0.1)

Application

The cables are designed to give good protection to the core against inductive interference (RF=0.1).The cables

are used for outdoor signaling equipment.

Standards

RENFE E.T. 03.365.051.6

Construction

Telephone CablesTelephone Cables

Conductors

Solid annealed bare copper 0.9/1.4mm as per ASTM B-3/class 1 of IEC 60228

Insulation

Solid polyethylene as per ASTM D 1248/IEC 60708

Cabling Element

Four insulated conductors are twisted together to form a quad

Cable Core Assembly

The cores are cabled together in concentric layers to form the cable core. Units are identified by colour coded

binders

Core Wrapping

One or more non-hygroscopic polyester tapes are helically or longitudinally laid with an overlap

Electrostatic Screen

One layer of copper wires 0.12mm is applied helically

Bedding

PE or LSZH

Electrostatic Armour

Two steel tapes of 0.5mm are helically applied with gap. The outer tape will cover the gap left by the inner one

Sheath

PE/PVC or LSZH

Ripcord

Nylon ripcord may be placed parallel to the cores to facilitate sheath removal

Electrical & Mechanical Properties

Nominal Conductor Diameter mm 0.9 1.4
Conductor Size mm2 0.636 1.539
Maximum Conductor Resistance @20°C Ω/km 28 12.1
Minimum Insulation Resistance @500V DC MΩ.km 35000 5000
Reduction Factor Rk (50Hz) Induced Voltage Em 100V/Km   0.1 0.1
                                     Induced Voltage Em 500V/Km   0.16 0.16
Maximum Resistance Unbalance % 2.5 2.5
Maximum Mutual Capacitance @0.8KHz nF/km 45 50
Maximum Capacitance Unbalance @1KHz pair-to-pair pF/500m 250 250
Maximum Capacitance Unbalance @1KHz pair-to-ground pF/500m 1200 1200
Maximum Average Attenuation @1KHz dB/km 0.7 0.46
Maximum Average Attenuation @10KHz dB/km 1.6 0.85
Maximum Average Attenuation @20KHz dB/km 2.1 1.3
Dielectric Strength Conductor to Conductor 3secs V DC 3000 3000
                           Conductor to Screen 3secs V DC 3500 3500
Minimum Insulation Thickness mm 0.45 0.65
Maximum Insulated Conductor Diameter mm 1.8 2.7

Mechanical and Thermal Properties

Temperature range during operation (fixed state): -30°C – +70°C

Temperature range during installation (mobile state): -20°C – +50°C

Minimum bending radius: 15 x Overall Diameter

Colour Code

Layer Quad Position Colour of conductors
1 2 3 4
Centre and even layers First ORANGE GREEN RED WHITE
Even YELLOW GREEN BLUE WHITE
Odd YELLOW GREEN RED WHITE
Last ORANGE GREEN BLUE WHITE
Odd Layers First ORANGE GREEN RED BLACK
Even YELLOW GREEN BLUE BLACK
Odd YELLOW GREEN RED BLACK
Last ORANGE GREEN BLUE BLACK

Dimensions And Weight

Cable Code Number of Quads Nominal Bedding/Sheath Thickness
mm
Nominal Overall
Diameter
mm
Nominal Weight kg/km
0.9mm Conductor, 1.8mm Insulated Wire
TP365-2Y(CTS)2Y(DSTA)Y1Q09-RF01 1 1.5/1.6 24.5 1300
TP365-2Y(CTS)2Y(DSTA)Y3Q09-RF01 3 1.5/1.6 25.5 1425
TP365-2Y(CTS)2Y(DSTA)Y5Q09-RF01 5 1.5/1.6 28.0 1650
TP365-2Y(CTS)2Y(DSTA)Y7Q09-RF01 7 1.5/1.6 29.5 1800
TP365-2Y(CTS)2Y(DSTA)Y25Q09-RF01 25 1.7/1.8 41.0 3175
1.4mm Conductor, 2.7mm Insulated Wire
TP365-2Y(CTS)2Y(DSTA)Y3Q14-RF01 3 1.5/1.6 28.5 1775
TP365-2Y(CTS)2Y(DSTA)Y5Q14-RF01 5 1.6/1.8 33.0 2200
TP365-2Y(CTS)2Y(DSTA)Y7Q14-RF01 7 1.6/1.8 35.5 2525
TP365-2Y(CTS)2Y(DSTA)Y10Q14-RF01 10 1.6/1.8 39.0 2975