Windmill Cables | |||
EPR/HFXLEVA LSOH 0.6/1kV Torsion Resistant Power Cable | HFEPR/HFEVA 0.6/1kV LSOH Screened Torsion Resistant Power Cable | Al Conductor EPR/XLEVA 0.6/1kV LSOH Power Cable 90℃ | more |
Windmill Cables
H07RN-F & UL/CSA 600V 90°C
Application
These cables are designed for use at medium mechanical stresses in wind turbines. They can be used in case of
protected and fixed installation in tubes or in equipment as well as rotor connecting cable of motors with a
working voltage up to 1000 V alternating voltage or a direct voltage up to 750 V against ground.
Standards
HD 22.4 S4
UL 758
Construction
Conductor: Stranded bare copper, fine wire class 5 according to IEC 60228/DIN VDE 0295/HD 383.
Insulation: EPR class 28.
Sheath: CPE class 42.
Technical Data
Rated Voltage Uo/U (Um):600V(UL/CSA)
Operating Temperatures:-40℃~+90℃
Minimum Bending Radius:flexing: 6×OD; fixed: 4×OD
Short-circuit Temperature:250℃
Flame Retardant:DIN EN 60332-1-2/IEC 60332-1-2
Oil Resistant:Yes
Ozone Resistant:Yes
UV Resistant:Yes
Dimensions and Weight
Construction | Nominal Overall Diameter | Nominal Weight |
---|---|---|
No. of cores×mm² | mm | kg/km |
1G25 | 13.9 | 385 |
1×50 | 17.8 | 680 |
1G95 | 22.4 | 1142 |
1×150 | 27.1 | 1845 |
1×240 | 32.1 | 2820 |
1×300 | 35.0 | 3390 |
1×400 | 40.0 | 4370 |
3G1 | 9.6 | 130 |
3G1.5 | 9.8 | 160 |
3G2.5 | 11.5 | 220 |
3G4 | 16.0 | 320 |
3G6 | 17.1 | 420 |
3G10 | 22.9 | 810 |
3×35 | 31.5 | 1850 |
3×50 | 35.5 | 2590 |
3×70 | 41.0 | 3560 |
3×95 | 46.0 | 4500 |
3×240 | 70.5 | 10260 |
4G1.5 | 10.5 | 200 |
4G2.5 | 12.5 | 280 |
4G4 | 14.5 | 380 |
4G6 | 18.4 | 540 |
4G10 | 25.0 | 950 |
5G1.5 | 11.5 | 250 |
5G2.5 | 13.5 | 350 |
5G4 | 18.7 | 485 |
5G6 | 20.1 | 650 |
7G1.5 | 13.5 | 400 |
7G2.5 | 15.5 | 540 |
G: with green-yellow earth core