S-3GSHCOEU 0.6/1 kV & UL 1000V 90°C

Application

These cables are designed for use at medium mechanical stresses in wind turbines.

Standards

UL 758

DIN VDE 0250

Construction

Windmill Cables

Conductor: Stranded bare copper, class 5 according to IEC 60228/DIN EN 60228.

Insulation: Rubber compound.

Screen: Tinned copper wires. Mixed braid of tinned copper wires and polyester yarn can be offered upon request.

Sheath: CPE.

Technical Data

Rated Voltage Uo/U (Um):600/1000V (DIN VDE 0250)/ 1000V (AWM 758)

Operating Temperatures:-40℃~+90℃

Maximum Permissible Tensile Load:15 N/mm²

Minimum Bending Radius:flexing: 10×OD; fixed: 6×OD

Short-circuit Temperature:250℃

Flame Retardant:IEC 60332-1

Oil Resistant:Yes

Ozone Resistant:Yes

UV Resistant:Yes

Dimensions and Weight

Construction Nominal Overall Diameter Nominal Weight
No. of cores×mm² mm kg/km
1×95 23.0 1120
1×120 26.0 1607
1×185 30.5 2341
1×240 34.0 2953