RG 6/U
APPLICATION
Airprot cables are designed for CCTV, security, smoke detection and evacuation monitoring applications, where
continued functionality is required during a fire situation. Due to the zero halogen low smoke construction, this
cable is ideal for use in public, commercial and industrial environments.
STANDARDS
Basic design to MIL-C-17
FIRE PERFORMANCE
FlameRetardance (SingleVerticalWireTest)** | EN60332-1-2; IEC60332-1-2; BSEN 60332-1-2; VDE0482-332-1; NBN C30-004 (cat.F1);NF C32-070-2.1(C2); CEI 20-35/1-2; EN 50265-2-1*; DIN VDE 0482-265-2-1* |
---|---|
Reduced FirePropagation(Vertically-mountedbundledwires &cabletest)** | EN60332-3-24(cat.C); IEC60332-3-24;BSEN60332-3-24;VDE0482-332-3;NBN C30-004 (cat.F2);NF C32-070-2.2(C1);CEI 20-22/3-4; EN 50266-2-4*; DIN VDE 0482-266-2-4 |
Note:
Asterisk * denotes superseded standard
Asterisk ** denotes that the standard compliance is optional, depending on the oxygen index of the PVC
compound and the cable design.
CABLE CONSTRUCTION
Conductors: Copper clad steel
Insulation: Foam PE compound.
Screen 1: Aluminium foil
Screen 2: Aluminium wire braid
Outer Sheath: Thermoplastic PVC compound.
Physical AND THERMAL PROPERTIES
Temperature range during operation (fixed state): -30°C - +70°C
Temperature range during installation (mobile state): -5ºC - +60ºC
Minimum bending radius: 8 x Overall Diameter
Electrical Properties
Impedance:75±5Ω
Capacitance:54NF/kM
Velocityratio(%):82
Insulation resistance:>5000Mohm.km
Shield coverage:70%
DC resistance
Inner conductor:23.1Ω/km
Outer conductor:31 Ω/km
Attenuation
Frequency(MHz) | Attenuation(dB/100m) | Attenuation(dB/100ft) |
---|---|---|
50 | 5.0 | 1.5 |
100 | 6.4 | 1.96 |
200 | 9.2 | 2.8 |
500 | 14.5 | 4.4 |
600 | 15.9 | 4.9 |
800 | 17.7 | 5.4 |
1000 | 21.9 | 6.7 |
1350 | 24.9 | 7.6 |
1750 | 29.0 | 8.8 |
2050 | 33.1 | 10.1 |
2400 | 36.4 | 11.1 |
CONSTRUCTION PARAMETERS
Cable Code | Conductor Diameter | Nominal Insulation Diameter | Nominal Screen No.xDiameter | Nominal Overall Diameter | Approx. Weight |
---|---|---|---|---|---|
mm | mm | No. x mm | mm | kg/km | |
RG6/U | 1.02 | 4.8 | 96*×0.12 | 7.0 | 43 |