RG7H1R for Airport Lighting
Applications
Airprot cables are used as airfield lighting equipment primary cables for the series circuit connecting the
Constant Current Regulators and the isolating transformers, and between the isolating transformers.
Standards
ENV 50213
Construction
Conductor: Compact stranded bare copper conductor.
Inner Semi-Conductor: Extruded semi-conducting compound.
Insulation: High module rubber compound, G7 type.
Outer Semi-Conductor: Extruded semi-conducting compound.
Shield: Bare copper tapes.
Sheath: PVC.
Technical Data
Rated Voltage Uo/U (Um) :3.6/6kV
Maximum Conductor Temperature :90℃
Short Circuit Temperature :250℃
Operating Temperatures :0℃~+90℃
Minimum Bending Radius ;15×OD
Flame Retardant :Yes
Dimensions and Weight
Construction | Nominal Insulation Thickness | Minimum Shield Thickness | Nominal Sheath Thickness | Nominal Overall Diameter |
Nominal Weight |
---|---|---|---|---|---|
No. ×mm² | mm | mm | mm | mm | kg/km |
1×10 | 2.3 | 0.075 | 1.4 | 14.0 | 305 |