Automotive Cable | |||
Automotive Cable
Germany Standard
Single-core cable
FLYY
Application
Automotive PVC insulated, PVC sheathedlow tension multi-cores cable is used for automobiles, motorcycles and
other motor vehicles.
Construction:
Conductor:
Cu-ETP1 bare or tinned according to DIN EN13602
Insulation:
PVC
Sheath:
PVC
Standard Compliance:
ISO 6722 Class B
Technical Parameters:
Operating temperature:–40 °C to +105 °C
Conductor | Insulation | Cable | |||||||
---|---|---|---|---|---|---|---|---|---|
Nominal cross- section |
No. and Dia. of Wires | Diameter Max. | Electrical resistance at 20℃ Bare/tinned Max. | thickness wall Nom. | Diameter of core | Sheath thickness | Overall Diameter min. | Overall Diameter max. | Weight approx. |
mm2 | No./mm | mm | mΩ/m | mm | mm | mm | mm | mm | Kg/km |
2x 0.50 | 16/0.21 | 1.00 | 37.10/38.20 | 0.50 | 1.75 | 0.50 | 4.30 | 4.70 | 31 |
2x 0.75 | 24/0.21 | 1.20 | 24.70/25.40 | 0.60 | 2.30 | 0.50 | 5.40 | 5.80 | 48 |
2x 1.00 | 32/0.21 | 1.35 | 18.50/19.10 | 0.60 | 2.50 | 0.80 | 6.40 | 6.80 | 65 |
2x 1.50 | 30/0.26 | 1.70 | 12.70/13.00 | 0.60 | 2.75 | 0.90 | 7.00 | 7.50 | 83 |
3x 0.50 | 16/0.21 | 1.00 | 37.10/38.20 | 0.50 | 2.10 | 0.60 | 5.80 | 6.20 | 53 |
3x 0.75 | 24/0.21 | 1.20 | 24.70/25.40 | 0.60 | 2.30 | 0.60 | 5.70 | 6.30 | 60 |
3x 1.00 | 32/0.21 | 1.35 | 18.50/19.10 | 0.60 | 2.50 | 0.90 | 6.90 | 7.50 | 81 |
3x 1.50 | 30/0.26 | 1.70 | 12.70/13.00 | 0.60 | 2.65 | 0.70 | 6.90 | 7.50 | 98 |
Note: Other co32nfigurations, sizes, colors and length not specified herein are available upon request.