High Temperature Cables
Thermocouple Cables

High Temperature Cables

SiHF-C-Si - Silicone Shielded Double Jacket Multi-Core Cable

Product application:

SiHF-C-Si  is a special 180 Degree C. silicone multi-core cable for use in high and low temperature areas or

whenever the insulation is subject to extreme temperature changes.  These cables are mainly found in steel

producing industry and aviation industry as well as in ship building, cement, glass and ceramic factories.  SIHF-C

-Si cables are low-smoke and halogen-free especially suited for use in power stations.  The silicone jacket

provides added heat, chemical, oil and acidic resistance while the internal tinned copper braid shield protects

against electromagnetic interference offering disturbance free signals and impulses. Not permitted for outdoor

use.

Product characteristic:

Construction:

Tinned copper conductor according to DIN VDE 0295 cl.5, BS 6360 cl.5 and IEC 60228 cl.5

Conductor insulation of silicone

Conductor identification according to DIN VDE 0293-308, single color, or black conductors with sequential

numbering imprinted in white, for 2 conductors brown, blue

Conductors stranded in layers with optimal lay-length

Green-yellow grounding (3 conductors)

Inner jacket of silicone

Braid of tinned Cu wires, coverage approx. 85%

Silicone-rubber-insulated common outer jacket

Jacket preferentially red brown color

Technical:

Special silicone-insulated cable with higher heat-resistance adapted to DIN VDE 0250 part 1 and part 816

Temperature range: -60°C to +180°C

Short time temp up to +220º C

Temperature limit at the conductor

in operation +180°C

Nominal voltage: 300/500 V

Test voltage: 2000 V

Insulation resistance :min. 200 MΩ x km

Minimum bending radius: flexing 10 x cableØ

5 x cableØ

Coupling resistance :max. 250Ω/km

Radiation resistance : up to 20x106 cJ/kg (up to 20 Mrad)

Properties:

Resistant to

High molecular oils, fats from vegetables and animals, alcohols, plasticizers and clophenes, diluted acids, lye and

salt dissolution, oxidation substances, tropical influences and weather, lake water, oxygen and UV

Halogen-free

According to DIN VDE 0482 part 267/ EN 50267-2-2/ IEC 60754-2 (equivalent DIN VDE 0472 part 813)

Burning behavior

No propagation of fire

Testing according to DIN VDE 0482 part 265-2-1/ EN 50265-2-1/ IEC 60332-1 (equivalent DIN VDE 0472 part 804

test method B)

For laying as a fixed installation only in open or ventilated pipe systems as well as in ducts. Otherwise the

mechanical properties of the silicon are reduced by the enclosed air at temperatures exceeding 90°C.

SiHF-C-Si - Silicone Shielded Double Jacket Multi-Core Cable

Product specification:  

AWG No. of Cores Conductor cross section
mm²
Nominal OD
mm
Copper weight
kg/km
Gross
Weight
kg/km
20 2 0.25 8.7 55.5 101
20 3 0.25 8.9 60.8 118
20 4 0.25 9.4 66.5 131
20 5 0.25 10 81.6 153
20 7 0.25 10.5 92.2 173
20 10 0.25 13.1 124 242
20 12 0.25 13.4 134.4 263
20 16 0.25 14.6 170.2 326
20 18 0.25 15.1 181 351
20 25 0.25 19.4 230.1 348
18 2 0.75 9.2 61.4 124
18 3 0.75 9.5 69.1 136
18 4 0.75 10.1 86.7 159
18 5 0.75 10.8 95.2 180
18 7 0.75 11.6 113.3 212
18 10 0.75 14.4 165.2 306
18 12 0.75 14.7 180.3 333
18 16 0.75 16.5 212.2 418
18 18 0.75 17.3 282.1 453
18 25 0.75 22.1 297.4 468
17 2 1 9.5 66.7 132
17 3 1 9.7 86.2 153
17 4 1 10.4 96.8 173
17 5 1 11.3 108.3 202
17 7 1 12 141.2 243
17 10 1 14.9 190 238
17 12 1 15.2 209.8 371
17 16 1 17 251.8 468
17 18 1 17.8 297.4 526
17 25 1 23 329 559
16 2 1.5 10.7 87.7 172
16 3 1.5 11.2 103.5 198
16 4 1.5 11.8 131.7 235
16 5 1.5 13.3 148.5 281
16 7 1.5 14.3 193.4 345
16 10 1.5 17.7 268.5 482
16 12 1.5 18 298.4 531
16 16 1.5 20.1 362.3 662
16 18 1.5 20.9 394 720
16 25 1.5 24.1 488.2 791
14 2 2.5 12.1 122.3 230
14 3 2.5 12.9 147.7 275
14 4 2.5 14.2 188.6 340
14 5 2.5 15.3 214.9 394
14 7 2.5 16.9 265.7 488
12 4 4 17.1 294 520
12 5 4 19.4 374 653
10 4 6 18.8 449 781
10 5 6 21.2 563 982
8 4 10 25.7 759 1294
6 4 16 28.4 1180 1988
4 4 25 35 1810 2995

Other sizes and colours available on request.