Industrial Cables  
American French German Harmonized Italian JIS Spanish

Industrial Cables-British Standard

3192Y to BS 6500(New BS EN 50525-2-11)

Application and Description

3192Y to BS 6500(New BS EN 50525-2-11) cables are suited for medium mechanical stress in damp and wet

environments such as refrigerators, washing machines, spin dryers and other appliances, as long as it meets

applicable equipment specifications. These cables are also suited for cooking and heating apparatus, provided

that the cable does not come into direct contact with the hot parts of the apparatus or with any other heat

source. Further applications of this cable include: Fixed installation in furniture, partition walls, decorative

covering, and in the hollow spaces of prefabricated building parts. They are not suitable for outdoor use,

industrial (except clothing manufacture) or farming applications. 2192Y is equivalent to harmonized code

H05VVH2-F.

Cable Construction

3192Y to BS 6500(New BS EN 50525-2-11)3192Y to BS 6500(New BS EN 50525-2-11)

Core Identification

Technical Characteristics

Cable Parameter

AWG
(No of Strands/
Strand
Diameter)
No. of Cores x Nominal Cross Sectional Area
#xmm²
Nominal Thickness
of Insulation
mm
Nominal Thickness of Sheath
mm
Nominal Overall Diameter
mm
Nominal Copper Weight kg/km Nominal Weight kg/km
3192Y
18(24/32) 2x0.75 0.6 0.8 4.2x6.8 14.4 49
17(32/32) 2x1.0 0.6 0.8 4.4x7.2 19.2 57
16(30/30) 2x1.5 0.7 0.8 4.7x7.9 29.0 79