HOMEPRODUCTSCABLE FOR OIL INDUSTRY

 

Individual & Overall Screened Thermocouple Cable

 

 

Cables for Oil Industry

Applications:

These cables are used with thermocouples for temperature measurements where hydrocarbon may be present.

Standards:

IEC 60584-3; NF C 42-324

Construction

Conductor: Metal according to thermocouple type

Insulation: PVC

Individual screen: Aluminum/polyester tape with tinned copper drain wire

Individual sheath: PVC

Overall screen: Aluminum/polyester tape with tinned copper drain wire

Sheath: Special PVC. Color depends on thermocouple type

Properties

Flame retardance: NFC 32070 C2, IEC 60332-1-2

Operating voltage: 250V

Operating temperature: -20~60°C

Max. conductor temperature in service: 70°C

Chemical resistance: Aliphatic and aromatic hydrocarbon resistance

Conductor Size (mm sq) No, of Pairs Min. O.D. (mm) Max. O.D. (mm) Approx. Weight (kg/km)
0.5 solid 3 11.1 12.8 180
0.5 solid 7 15.4 17.7 335
0.5 solid 12 19.8 22.8 545
0.5 solid 19 24.6 28.1 825
0.5 solid 27 28.9 33.2 1135