Flame Retardant Coaxial Cables
Flame Retardant RG59 B/U Coaxial cables
APPLICATION :
The cables are designed for CCTV, security, smoke detection and evacuation monitoring applications, where continued functionality is required during a fire situation. Due to the zero halogen low smoke construction, this cable is ideal for use in public, commercial and industrial environments.
STANDARDS:
Basic design adapted to MIL-C-17
FIRE PERFORMANCE:
Flame Retardance (Single Vertical Wire Test)** | EN 60332-1-2; IEC 60332-1-2; BS EN 60332-1-2; VDE 0482-332-1 ; NBN C 30-004 (cat. F1); NF C32-070-2.1(C2); CEI 20-35/1-2; EN 50265-2-1*; DIN VDE 0482-265-2-1* |
---|---|
Reduced Fire Propagation (Vertically-mounted bundled wires & cable test)** | EN 60332-3-24 (cat. C); IEC 60332-3-24; BS EN 60332-3-24; VDE 0482-332-3; NBN C 30-004 (cat. F2); NF C32-070-2.2(C1); CEI 20-22/3-4; EN 50266-2-4*; DIN VDE 0482-266-2-4 |
Note: Asterisk ** denotes that the standard compliance is optional, depending on the oxygen index of the PVC
compound and the cable design.
CABLE CONSTRUCTION :
Conductors: Copper clad steel, solid according to IEC(EN) 60228 class 1.
Insulation: PE compound.
Overall Screen: Plain copper wire braid
Outer Sheath: Thermoplastic PVC compound. UV resistance, hydrocarbon resistance, oil resistance, anti rodent and anti termite properties can be offered as option. Compliance to fire performance standard (IEC 60332-1, IEC 60332-3, UL 1581, UL 1666 etc) depends on the oxygen index of the PVC compound and the overall cable design. LSPVC can also be provided upon request.
Physical AND THERMAL PROPERTIES:
Temperature range during operation (fixed state): -30°C - +70°C
Temperature range during installation (mobile state): -5ºC - +60ºC
Minimum bending radius: 8 x Overall Diameter
Electrical Properties:
Impedance | 75±5Ω |
---|---|
Capacitance | 67 NF/KM |
Velocity ratio(%) | 66 |
Insulation resistance | >2000 Mohm.Km |
Shield coverage | 95% |
DC resistance | |
Inner conductor | 158 Ω/km |
Outer conductor | 9.0 Ω/km |
Attenuation:
Frequency(MHz) | Attenuation (dB/100 m) | Attenuation (dB/100ft) |
---|---|---|
50 | 7.4 | 2.26 |
100 | 10.7 | 3.26 |
200 | 15.7 | 4.79 |
400 | 22.7 | 6.92 |
500 | 25.7 | 7.84 |
600 | 28.7 | 8.75 |
860 | 34.8 | 10.61 |
1000 | 38.0 | 11.59 |
Return Loss:
Frequency(MHz) | Return Loss (dB) |
---|---|
30-300 MHz | >31dB |
300-600 MHz | >28dB |
600-900 MHz | >24dB |
CONSTRUCTION PARAMETERS:
Cable Code |
Conductor Diameter |
Nominal Insulation Diameter | Nominal Screen No.x Diameter |
Nominal Overall Diameter | Approx. Weight |
---|---|---|---|---|---|
mm | mm | No. x mm | mm | kg/km | |
FGD-RG59 b/U | 0.58 ± 0.03 | 3.70 ± 0.10 m | 120 x 0.15 | 6.20 | 60.3 |