HOMEPRODUCTS FIRE RESISTING CABLES(Fireguard)

 

Flame Retardant Coaxial Cables

Flame Retardant RG59 B/U Coaxial cables

 

 

APPLICATION :

The cables are designed for CCTV, security, smoke detection and evacuation monitoring applications, where continued functionality is required during a fire situation. Due to the zero halogen low smoke construction, this cable is ideal for use in public, commercial and industrial environments.

STANDARDS:

Basic design adapted to MIL-C-17

Flame Retardant RG59 B/U Coaxial cables

FIRE PERFORMANCE:

Flame Retardance (Single Vertical Wire Test)**

EN 60332-1-2; IEC 60332-1-2; BS EN 60332-1-2; VDE

0482-332-1 ; NBN C 30-004 (cat. F1); NF C32-070-2.1(C2); CEI 20-35/1-2; EN 50265-2-1*; DIN

VDE 0482-265-2-1*

Reduced Fire Propagation (Vertically-mounted bundled wires & cable test)**

EN 60332-3-24 (cat. C); IEC 60332-3-24; BS EN 60332-3-24; VDE 0482-332-3; NBN C 30-004

(cat. F2); NF C32-070-2.2(C1); CEI 20-22/3-4; EN 50266-2-4*; DIN VDE 0482-266-2-4

Note: Asterisk ** denotes that the standard compliance is optional, depending on the oxygen index of the PVC

compound and the cable design.

CABLE CONSTRUCTION :

Conductors: Copper clad steel, solid according to IEC(EN) 60228 class 1.

Insulation: PE compound.

Overall Screen: Plain copper wire braid

Outer Sheath: Thermoplastic PVC compound. UV resistance, hydrocarbon resistance, oil resistance, anti rodent and anti termite properties can be offered as option. Compliance to fire performance standard (IEC 60332-1, IEC 60332-3, UL 1581, UL 1666 etc) depends on the oxygen index of the PVC compound and the overall cable design. LSPVC can also be provided upon request.

Physical AND THERMAL PROPERTIES:

Temperature range during operation (fixed state): -30°C - +70°C

Temperature range during installation (mobile state): -5ºC - +60ºC

Minimum bending radius: 8 x Overall Diameter

Electrical Properties:

Impedance 75±5Ω
Capacitance 67 NF/KM
Velocity ratio(%) 66
Insulation resistance >2000 Mohm.Km
Shield coverage 95%
DC resistance  
Inner conductor 158 Ω/km
Outer conductor 9.0 Ω/km

Attenuation:

Frequency(MHz) Attenuation (dB/100 m) Attenuation (dB/100ft)
50 7.4 2.26
100 10.7 3.26
200 15.7 4.79
400 22.7 6.92
500 25.7 7.84
600 28.7 8.75
860 34.8 10.61
1000 38.0 11.59

Return Loss:

Frequency(MHz) Return Loss (dB)
30-300 MHz >31dB
300-600 MHz >28dB
600-900 MHz >24dB

CONSTRUCTION PARAMETERS:

Cable
Code
Conductor
Diameter
Nominal Insulation Diameter Nominal
Screen
No.x Diameter
Nominal Overall Diameter Approx. Weight
  mm mm No. x mm mm kg/km
FGD-RG59 b/U 0.58 ± 0.03 3.70 ± 0.10 m 120 x 0.15 6.20 60.3