HOMEPRODUCTS FIRE RESISTING CABLES

 

Flame Retardant Coaxial Cables

Flame Retardant RG11 Coaxial Cables

 


Application :

These 75Ω coaxial cables are suitable for installation on board of ships and other indoor marine environments.

Standards:

Basic design to MIL-C-17

Flame Retardant RG11 Coaxial Cables

Fire Performance:

Flame Retardance (Single Vertical Wire Test)

EN 60332-1-2; IEC 60332-1-2; BS EN 60332-1-2; VDE

0482-332-1 ; NBN C 30-004 (cat. F1); NF C32-070-2.1(C2); CEI 20-35/1-2; EN 50265-2-

1*; DIN VDE 0482-265-2-1*

Reduced Fire Propagation (Vertically-mounted bundled wires & cable test)

EN 60332-3-24 (cat. C); IEC 60332-3-24; BS EN 60332-3-24; VDE 0482-332-3; NBN C 30-

004 (cat. F2); NF C32-070-2.2(C1); CEI 20-22/3-4; EN 50266-2-4*; DIN VDE 0482-266-2-

4

Halogen Free

IEC 60754-1; EN 50267-2-1; DIN VDE 0482-267-2-1; CEI 20-37/2-1 ; BS 6425-1*

No Corrosive Gas Emission

IEC 60754-2; EN 50267-2-2; DIN VDE 0482-267-2-2; CEI 20-37/2-2 ; BS 6425-2*

minimum Smoke Emission

IEC 61034-1&2; EN 61034 -1&2; DIN VDE 0482-1034-1&2; CEI 20-37/3-1&2; EN 50268-

1&2*; BS 7622-1&2*

No Toxic gases

NES 02-713; NF C 20-454

Note: Asterisk * denotes superseded standard.

Cable Construction :

Conductors: 14AWG solid bare copper.

Insulation: Low density PE compound.

Screen1: Aluminium/polyester or aluminium tape.

Screen2: Tinned copper braid.

Inner Sheath: Low smoke and halogen-free polyolefin, coloured black.

Armour:

cwb: copper Wire Braidswb: Steel Wire Braid

swa: Steel Wire Armour

Outer Sheath: Thermoplastic LSZH compound type LTS3 as per BS 7655-6.1 (Thermosetting LSZH compound type SW2-SW4 as per BS 7655:section 2.6 can be offered.)

Physical And Thermal Properties:

Temperature range during operation (fixed state): -30°C - +75°C

Minimum bending radius: 15 x Overall Diameter

Electrical Properties:

AWG   14
Nominal Conductor Diameter mm 1.6
Impedance Ω 75+/-5
Nominal Attenuation@100mHz dB/100m 4.5
Nominal Attenuation@270mHz dB/100m 7.6
Nominal Attenuation@540mHz dB/100m 10.8
Nominal Attenuation@750mHz dB/100m 12.8
Nominal Attenuation@1000mHz dB/100m 14.8
Capacitance pF/m 53.5
Velocity of Propagation % 83
Conductor DCR Ω/km 8.5
Shield DCR Ω/km 12.1
Inductance μH/m 0.32
Time Delay ns/m 4

Construction Parameters:

Cable Code Nominal Inner Conductor Diameter Nominal Insulation Thickness Nominal Sheath Thickness Nominal Overall Diameter Nominal
Weight
  mm mm mm mm kg/km
RG11 CWB 1.6 2.7 1.7 15.2 349
RG11 SWB 1.6 2.7 1.7 15.2 344
RG11 SWA 1.6 2.7 1.7 16.2 468