HOMEPRODUCTS FIRE RESISTING CABLES

 

Flame Retardant Coaxial Cables

Flame Retardant RG6 Coaxial cables

 

Application :

The cables are designed for CCTV, security, smoke detection and evacuation monitoring applications, where continued functionality is required during a fire situation. Due to the zero halogen low smoke construction, this cable is ideal for use in public, commercial and industrial environments.

Standards:

Basic design to MIL-C-17

Flame Retardant RG6 Coaxial cables

Fire Performance:

Flame Retardance (Single Vertical Wire Test)

EN 60332-1-2; IEC 60332-1-2; BS EN 60332-1-2; VDE

0482-332-1 ; NBN C 30-004 (cat. F1); NF C32-070-2.1(C2); CEI 20-35/1-2; EN 50265-2-

1*; DIN VDE 0482-265-2-1*

Reduced Fire Propagation (Vertically-mounted bundled wires & cable test)

EN 60332-3-24 (cat. C); IEC 60332-3-24; BS EN 60332-3-24; VDE 0482-332-3; NBN C 30-

004 (cat. F2); NF C32-070-2.2(C1); CEI 20-22/3-4; EN 50266-2-4*; DIN VDE 0482-266-2-

4

Halogen Free

IEC 60754-1; EN 50267-2-1; DIN VDE 0482-267-2-1; CEI 20-37/2-1 ; BS 6425-1*

No Corrosive Gas Emission

IEC 60754-2; EN 50267-2-2; DIN VDE 0482-267-2-2; CEI 20-37/2-2 ; BS 6425-2*

minimum Smoke Emission

IEC 61034-1&2; EN 61034 -1&2; DIN VDE 0482-1034-1&2; CEI 20-37/3-1&2; EN 50268-

1&2*; BS 7622-1&2*

No Toxic gases

NES 02-713; NF C 20-454

Note: Asterisk * denotes superseded standard.

Cable Construction :

Conductors: Bare copper copper wire, solid according to IEC(EN) 60228 class 1.

Insulation: Foamed PE compound.

Overall Screen: Aluminium foil(100%)+Aluminium braid (70%)

Outer Sheath: Thermoplastic LSZH compound type LTS3 as per BS 7655-6.1 (Thermosetting LSZH compound type SW2-SW4 as per BS 7655-2.6 can be offered.)

Physical And Thermal Properties:

Temperature Range During Operation (Fixed State): -30°C - +70°C

Temperature Range During Installation (Mobile State): -5°C - +60°C

Minimum Bending Radius: 8 X Overall Diameter

Electrical Properties:

ImPEDANCE 75±5Ω
CAPACITANCE 54 NF/Km
Velocity ratio(%) 82
Insulation resistance >5000 mohm.Km
Shield coverage AL FOIL(100%)+AL 70%
DC resistance  
Inner conductor 23.1 Ω/km
Outer conductor 31 Ω/km

Att enuation:

Frequency(MHz) Attenuation (dB/100 m) Attenuation (dB/100ft)
50 5.0 1.5
100 6.4 1.96
200 9.2 2.8
500 14.5 4.4
600 15.9 4.9
800 17.7 5.4
1000 21.9 6.7
1350 24.9 7.6
1750 29.0 8.8
2050 33.1 10.1
2400 36.4 11.1

Return Loss:

Frequency(MHz) Return Loss (dB)
30-300 >28dB
300-600 >24dB
600-900 >22dB

Construction Parameters:

Cable
Code
Conductor
Diameter
Nominal Insulation Diameter Nominal
Screen
No.x Diameter
Nominal Overall Diameter Approx. Weight
  mm mm No. x mm mm kg/km
RG6 A/U 1.02 4.57 ± 0.20 96 x 0.12 7.00 81.6