HOMEPRODUCTS MARINE CABLES

 

Marine Cable

P16 IFLI 250 V

 

Applications :

    Marine cables are flame retardant, low smoke and halogen free, used for living, quarter and office areas.

Standards :

IEC 60092-376

IEC 60092-360

IEC 60332-1

IEC 60332-3-22

IEC 60754-1,2

IEC 61034-1,2

NEK 606

IEC60092 Offshore & Marine CablesIEC60092 Offshore & Marine Cables

Construction :

Conductors : Circular stranded copper wire to IEC 60228 class 2.

Insulation : XLPE.

Bedding : Halogen free thermoplastic compound.

Metal Screen : Longitudinal aluminium tape, thickness 0.2 mm in contact with a stranded copper earth conductor.

Outer Sheath : Halogen free thermoplastic compound, SHF1, coloured grey.

Electrical Characteristics :

    Nominal Cross Section Area mm² 2.5
    Maximum Resistant@20℃ Ω/km 7.41
    Continuous Current Rating@45℃2 Core A 26
    Short Circuit Current 1s A 360
    Operating Voltage V 250

Mechanical and Thermal Properties :

Bending Radius : 8×OD (during installation); 6×OD (fixed installed).

Temperature Range : -20℃ ~ +90℃.

Dimensions and Weight :

Construction No. of elements×No. of cores in element×Cross section
(mm²)
Nominal Insulation Thickness
mm
Nominal Sheath Thickness
mm
Nominal Overall Diameter
mm
Nominal Weight
kg/km
Inner Outer
2×1×2.5 0.7 1.1 1.2 10.0 180