Marine Cable
RG58 Armoured Coaxial Cable
Applications :
Marine 50Ω coaxial cables are suitable for installation on board of ships and other indoor marine environments.
Standards :
IEC 60092-350
IEC 60332-3-22
IEC 60754-1,2
IEC 61034-1,2
NEK 606
Construction :
Conductors : 21AWG tinned copper.
Insulation : PE.
Shielding : Tinned copper braid.
Bedding : Low smoke and halogen-free polyolefin, coloured black.
Armour : Copper wire braid.
Outer Sheath : Low smoke and halogen-free polyolefin.
Electrical Characteristics :
AWG | 21 | |
---|---|---|
Conductor Construction No./Diameter of Wires | -/mm | 19/0.18 |
Nominal Conductor Diameter | mm | 0.89 |
Impedance | Ω | 50+/-3 |
Nominal Attenuation@100MHz | dB/100m | 15.7 |
Nominal Attenuation@200MHz | dB/100m | 22.3 |
Nominal Attenuation@400MHz | dB/100m | 32.8 |
Nominal Attenuation@700MHz | dB/100m | 46.6 |
Nominal Attenuation@900MHz | dB/100m | 54.1 |
Nominal Attenuation@1000MHz | dB/100m | 56.1 |
Capacitance | pF/m | 101 |
Velocity of Propagation | % | 66 |
Conductor DCR | Ω/km | 35.4 |
Inductance | μH/m | 0.246 |
Time Delay | ns/m | 5.0 |
Mechanical and Thermal Properties :
Bending Radius : 15×OD.
Temperature Range : -30℃ ~ +75℃.
Dimensions and Weight :
Nominal Inner Conductor Diameter mm |
Nominal Insulation Thickness mm |
Nominal Sheath Thickness mm |
Nominal Overall Diameter mm |
Nominal Weight kg/km |
---|---|---|---|---|
0.89 | 1.0 | 1.14 | 8.6 | 149 |