UKOOA TYPE GL / TYPE GN 150/250V Fire Resistant
Application:
Marine cables are designed for fixed installation for control and lighting in both and safe areas, emergency and critical offshore applications where cable protection is required.
Standards:
BS 6883/BS 7917/UKOOA
IEC 60331-21
IEC 60332-3-22 CAT. A
IEC 60332-1
IEC 60754-1 & IEC 60754-2
IEC 61034-1 & IEC 61034-2
Construction:
Conductors:Stranded class 2 or flexible class 5 tinned annealed copper conductors to BS 6360/IEC 60228.
Fire Protection:Mica glass tape
Insulation:EPR complying with BS7655 GP4
Drain Wire:Tinned copper drain wire
Collective Screen:Aluminium mylar tape screen
Bedding:EVA - SW4 compound complying with BS 7655
Armour :Galvanised steel wire braid to BS 6883
Outer Sheath :EVA - SW4 compound complying with BS 7655 (TYPE GL: Blue; TYPE GN: Grey)
Dimensions and Weight:
Construction No. of cores×Cross section |
Nominal Insulation Thickness |
Nominal Thickness of Inner Sheath |
Nominal Thickness of Outer Sheath |
Nominal Overall Diameter |
Approx. Weight |
---|---|---|---|---|---|
mm² | mm | mm | mm | mm | kg/km |
3×2×0.75 | 0.8 | 1.2 | 1.4 | 17.8 | 520 |
7×2×0.75 | 0.8 | 1.4 | 1.5 | 22.0 | 780 |
12×2×0.75 | 0.8 | 1.6 | 1.7 | 27.6 | 1150 |
20×2×0.75 | 0.8 | 1.8 | 2.0 | 35.3 | 1900 |
3×3×0.75 | 0.8 | 1.3 | 1.5 | 20.0 | 520 |
7×3×0.75 | 0.8 | 1.5 | 1.7 | 25.3 | 870 |
12×3×0.75 | 0.8 | 1.8 | 2.0 | 33.6 | 1500 |
1×4×0.75 | 0.8 | 1.2 | 1.2 | 17.1 | 390 |
1×2×1.0 | 0.8 | 1.0 | 1.0 | 14.0 | 180 |
1×3×1.0 | 0.8 | 1.0 | 1.0 | 14.3 | 300 |
1×4×1.0 | 0.8 | 1.1 | 1.2 | 15.3 | 430 |
1×2×1.5 | 0.8 | 1.2 | 1.3 | 14.4 | 320 |
3×2×1.5 | 0.8 | 1.3 | 1.4 | 23.4 | 771 |
7×2×1.5 | 0.8 | 1.4 | 1.6 | 29.2 | 1189 |
12×2×1.5 | 0.8 | 1.7 | 1.9 | 37.3 | 1869 |
3×3×1.5 | 0.8 | 1.3 | 1.3 | 27.7 | 979 |
7×3×1.5 | 0.8 | 1.5 | 1.5 | 35.1 | 1594 |
12×3×1.5 | 0.8 | 1.8 | 1.8 | 46.3 | 2647 |
1×4×1.5 | 0.8 | 1.2 | 1.4 | 19.2 | 600 |