UKOOA TYPE KG / TYPE KJ 150/250V Flame Retardant
Application:
Marine cables are designed for fixed installation for control and lighting in both and safe areas, emergency and critical offshore applications where cable protection is required.
Standards:
BS 6883/BS 7917/UKOOA
IEC 60332-3-22 CAT. A
IEC 60332-1
IEC 60754-1 & IEC 60754-2
IEC 61034-1 & IEC 61034-2
Construction:
Conductors:Stranded class 2 or flexible class 5 tinned annealed copper conductors to BS 6360/IEC 60228.
Insulation:EPR complying with BS7655 GP4
Drain Wire: Tinned copper drain wire
Collective Screen:Aluminium mylar tape screen
Bedding:EVA - SW4 compound complying with BS 7655
Armour :Galvanised steel wire braid to BS 6883
Outer Sheath :EVA - SW4 compound complying with BS 7655 (TYPE KG: Blue; TYPE KJ: Grey).
Dimensions and Weight:
Construction No. of cores×Cross section (mm²) |
Nominal Insulation Thickness mm |
Nominal Thickness of Inner Sheath mm |
Nominal Thickness of Outer Sheath mm |
Nominal Overall Diameter mm |
Approx. Weight kg/km |
---|---|---|---|---|---|
1×2×0.75 | 0.8 | 1.2 | 1.25 | 12.9 | 200 |
3×2×0.75 | 0.8 | 1.2 | 1.4 | 17.9 | 468 |
7×2×0.75 | 0.8 | 1.4 | 1.7 | 22.4 | 706 |
12×2×0.75 | 0.8 | 1.6 | 1.7 | 28.0 | 1030 |
20×2×0.75 | 0.8 | 1.8 | 2.0 | 35.2 | 1662 |
1×3×0.75 | 0.8 | 1.0 | 1.25 | 13.5 | 285 |
3×3×0.75 | 0.8 | 1.3 | 1.2 | 20.4 | 680 |
7×3×0.75 | 0.8 | 1.5 | 1.4 | 26.0 | 1325 |
12×3×0.75 | 0.8 | 1.7 | 1.7 | 34.6 | 2106 |
1×2×1.0 | 0.8 | 1.0 | 1.0 | 13.4 | 180 |
1×3×1.0 | 0.8 | 1.1 | 1.1 | 14.0 | 300 |
1×4×1.0 | 0.8 | 1.1 | 1.2 | 15.0 | 180 |
1×2×1.5 | 0.8 | 1.1 | 1.2 | 13.5 | 297 |
3×2×1.5 | 0.8 | 1.3 | 1.4 | 19.8 | 593 |
7×2×1.5 | 0.8 | 1.4 | 1.6 | 25.0 | 929 |
12×2×1.5 | 0.8 | 1.7 | 1.9 | 32.6 | 1510 |
20×2×1.5 | 0.8 | 1.9 | 2.1 | 39.9 | 2287 |
1×3×1.5 | 0.8 | 1.1 | 1.2 | 14.0 | 304 |
3×3×1.5 | 0.8 | 1.3 | 1.5 | 23.7 | 760 |
7×3×1.5 | 0.8 | 1.5 | 1.7 | 30.5 | 1262 |
12×3×1.5 | 0.8 | 1.8 | 2.0 | 40.7 | 2148 |
1×2×2.5 | 0.8 | 1.1 | 1.2 | 15.1 | 320 |