HOMEPRODUCTS RAILWAY CABLES

 

FRA 400 SW4

 

Applications :

These cables are designed for flexible installations, inside and outside railway rolling stock.

Standards :

DIN 5510-2

Construction :

FRA 316 SW4FRA 316 SW4

Inner conductor:Stranded silverplated copper.

Insulation:Crosslink Foam PE(SPEX).

Outer conductor(shield1):Silver plated copper.

Outer conductor(shield2):Silver plated copper.

Sheath:LSZH Elastomer.

Electrical Characteristics at 20 °C :

Impedance Ω 50+/-2
Nomina lCapacitance pF/m 94.5
Minimum Insulation Resistance MΩ.km 100000
Inner Conductor Resistance MΩ/km 29.45
Outer Conductor Resistance MΩ/km 7.6
Attenuation  
@10MHz dB/100m 5
@50MHz dB/100m 11
@100MHz dB/100m 16
@150MHz dB/100m 20
@200MHz dB/100m 23
@300MHz dB/100m 29
@400MHz dB/100m 34
@450MHz dB/100m 36
@500MHz dB/100m 38
@600MHz dB/100m 42
@800MHz dB/100m 50
@850MHz dB/100m 51
@900MHz dB/100m 53
@950MHz dB/100m 55
@1000MHz dB/100m 56
@1800MHz dB/100m 79
@1900MHz dB/100m 82
@2000MHz dB/100m 84
@2400MHz dB/100m 94
@3000MHz dB/100m 107
@4000MHz dB/100m 128
@5000MHz dB/100m 147
@6000MHz dB/100m 165
Velocity of propagation % 70.7

Mechanical and Thermal Properties :

  • Minimum Bending Radius:25mm (static)

  • Temperature Range:-40℃~+105℃

Dimensions and Weight :

Conductor Construction No/mm NominalInner Conductor Diameter mm NominalOuter Conductor Diameter mm NominalOverall Diameter mm NominalWeight
19/0.2 1.0 4.24 5.0 60