Rolling Stock Cable
FIREROL Thin Wall Multicore Cables with Exposed Standard Wall Sheath 300/500 V
EN 50306-4 (FRL-TW-05M-ESW)
A.Conductor B.Insulation C.Sheath
Application:
Used as power and control cable for protected installations inside and outside of rail and transport vehicles, where handling and installation cost are an important factor.
Used in control, auxillary and main circuit wiring such as cable harnesses, switchboards and control panels, driver desks etc.
Construction:
Conductor : Tinned annealed copper wires as defined in EN 50306-2
Insulation: LSZH special compound
Outer sheath: LSZH special compound (S2. EM101- EM104)
Electrical & Mechanical Properties:
Nominal Voltage:300/500 V
Maximum Conductor Temperature:+90/+105 deg (fixed installation)
Minimum Permissible Ambient Temperature:-25/-40 deg (fixed installation)
Bending Radius:3 x Overall Diameter (D<12mm);
4 x Overall Diameter (D>12mm)
Chemical & Environmental Properties:
EN 60684-2:No fluorine
EN 50305; EN 60811-2-1:Resistance to mineral oil & fuel oil, acid & alkali
EN 50305:Resistance to ozone
Fire Performance for rolling stock application:
EN 50306-2:Hazard levels HL1, HL2/HL3
DIN 5510-2:Protection level 1/2/3/4
BS 6853:Interior use 1a, 1b, II; Exterior use 1a, 1b, II
NF F 16-101:FO
EN45545-2:R15 Interior/ R16 Exterior HL1, HL2, HL3
Fire Performance in general:
EN 50265-2-1; IEC 60332-1-2; NF C 32-070 2.1 (C2) | Vertical flame propogation for a single insulated wire or cable |
---|---|
EN 50266-2-4 + EN 50305; IEC 60332-3-24; NF C 32-070 2.2 (C1); VDE 0472 Teil 804 |
Vertical flame spread of vertically mounted bunched wires or cables |
EN 50268-2; IEC 61034-2; NF C 32-073 ; NF C 20-902; NF F 16 101; VDE 0472 Teil 816 |
Low Smoke Emission |
EN 50267-2-1; IEC 60754-1; NF C 32-074;NF C 20-454; VDE 0472 Teil 815 | Halogen Free |
EN 50267-2-2/3; IEC 60754-2; NF C 32-074;NF C 20-453; VDE 0472 Teil 813 | Low Corrosivity (Acidity & Conductivity) |
EN 50305; NFX 70-100; NFF 63808; TM1-04; BS6853 | Low Toxicity |
NFF 16101; NFF 63808; BS6853 | Smoke index |
EN45545-2 | Requirement for fire behavior of materials & components R15/R16 |
FRL-TW-05M-ESW 300/500 V
NUMBER OF CORES AND NOMINAL CROSS SECTION | MINIMUM THICKNESS OF SHEATH AT ANY POINT | OVERALL DIAMETER | WEIGHT | |
---|---|---|---|---|
mm2 | mm | min. mm | max. mm | kg/km |
4 x 0.5 | 1.0 | 5.5 | 6.5 | 50 |
7 x 0.5 | 1.0 | 6.3 | 7.3 | 70 |
13 x 0.5 | 1.0 | 8.3 | 9.3 | 120 |
19 x 0.5 | 1.0 | 9.0 | 10.2 | 150 |
37 x 0.5 | 1.0 | 12.3 | 13.5 | 290 |
4 x 0.75 | 1.0 | 6.0 | 7.0 | 60 |
7 x 0.75 | 1.0 | 6.9 | 7.9 | 90 |
13 x 0.75 | 1.0 | 9.1 | 10.3 | 150 |
19 x 0.75 | 1.0 | 10.0 | 11.2 | 200 |
37 x 0.75 | 1.0 | 13.2 | 14.4 | 360 |
48 x 0.75 | 1.0 | 14.8 | 16.4 | 460 |
4 x 1.0 | 1.0 | 6.3 | 7.3 | 70 |
7 x 1.0 | 1.0 | 7.3 | 8.3 | 110 |
13 x 1.0 | 1.0 | 9.7 | 10.9 | 180 |
19 x 1.0 | 1.0 | 10.7 | 11.9 | 250 |
37 x 1.0 | 1.0 | 14.0 | 15.6 | 450 |
4 x 1.5 | 1.0 | 7.4 | 8.4 | 100 |
7 x 1.5 | 1.0 | 8.6 | 9.8 | 150 |
13 x 1.5 | 1.0 | 11.7 | 12.9 | 270 |
19 x 1.5 | 1.0 | 13.0 | 14.2 | 370 |
37 x 1.5 | 1.0 | 17.2 | 18.8 | 690 |
2 x 2.5 | 1.0 | 7.7 | 8.7 | 90 |
3 x 2.5 | 1.0 | 8.1 | 9.1 | 120 |
4 x 2.5 | 1.0 | 8.8 | 10.0 | 150 |