Category 5E Data Cables
FRL-Cat5E-4C0.5S, FRL-Cat5E-4C22A, FRL-Cat5E-4P22A
A. Conductor B. Insulation C. Screen D. Sheath
Application:
The cables are designed for permanently protected installation, inside and outside railway rolling stock, buses and other vehicles to connect fixed parts. Ethernet based networks as: infotainment, multimedia, passenger information system etc.
Construction:
For 4 x 0.5mm2, 4 x 22AWG cables
Conductors: Stranded tin plated copper conductor (for 0.5mm2 cables) or stranded silver plated copper
conductor (for 22AWG cables) according to IEC 60228 class 5.
Insulation:PE.
Cable Element: Individual conductor stranded together
EMC Screen1:Plastic laminated aluminium-tape.
EMC Screen2:Tin plated copper braid
Core Wrapping:Plastic tape(s).
Outer Sheath:Electron beam crosslinkable compound.
For 4 x 2 x 22AWG cables
Center: PE filler.
4 pairs 2 x 22AWG: Stranded tin plated copper conductor according to IEC 60228 class 5
Insulation:Electron beam crosslinkable compound.
EMC Screen1:Plastic laminated aluminium-tape.
EMC Screen2:Tin plated copper braid
Core Wrapping:Plastic tape(s).
Outer Sheath:Electron beam crosslinkable compound.
Electrical & Mechanical Properties:
Nominal Voltage:300V
Maximum Conductor Temperature:90℃
Minimum Permissible Ambient Temperature:-40°C
Bending Radius:6 x Overall Diameter
Chemical & Environmental Properties:
EN 60684-2:No fluorine
EN 50305; EN 60811-2-1:Resistance to mineral oil & fuel oil, acid & alkali
EN 50305:Resistance to ozone
Fire Performance for rolling stock application:
EN 50306-2:Hazard levels HL1, HL2/HL3
DIN 5510-2:Protection level 1/2/3/4
BS 6853:Interior use 1a, 1b, II; Exterior use 1a, 1b, II
NF F 16-101:FO
EN45545-2:R15 Interior/ R16 Exterior HL1, HL2, HL3
Fire Performance in general:
EN 50265-2-1; IEC 60332-1-2; NF C 32-070 2.1 (C2) | Vertical flame propogation for a single insulated wire or cable |
---|---|
EN 50266-2-4 + EN 50305; IEC 60332-3-24; NF C 32-070 2.2 (C1); VDE 0472 Teil 804 |
Vertical flame spread of vertically mounted bunched wires or cables |
EN 50268-2; IEC 61034-2; NF C 32-073 ; NF C 20-902; NF F 16 101; VDE 0472 Teil 816 |
Low Smoke Emission |
EN 50267-2-1; IEC 60754-1; NF C 32-074;NF C 20-454; VDE 0472 Teil 815 | Halogen Free |
EN 50267-2-2/3; IEC 60754-2; NF C 32-074;NF C 20-453; VDE 0472 Teil 813 | Low Corrosivity (Acidity & Conductivity) |
EN 50305; NFX 70-100; NFF 63808; TM1-04; BS6853 | Low Toxicity |
NFF 16101; NFF 63808; BS6853 | Smoke index |
EN45545-2 | Requirement for fire behavior of materials & components R15/R16 |
FRL-Cat5E-4C0.5S
Nominal Cross Sectional Area |
Nominal Sheath Thickness | Nominal Overall Diameter | Nominal Weight | Maximum Conductor Resistance 20°C | Maximum Resistance Unbalance | Characteristic Impedance | Transfer Impedance | Maximum Capacitance | |
---|---|---|---|---|---|---|---|---|---|
@100MHz | f≤30MHz | core to core | Core to screen | ||||||
mm2 | mm | mm | kg/km | Ω/km | Ω/km | Ω | mΩ/m | pF/m | pF/m |
0.5 | 1.2 | 8.3 | 102 | 40.1 | 1.1 | 100+/-5 | 200 | 65 | 100 |
FRL-Cat5E-4C22A
Nominal Cross Sectional Area |
Nominal Sheath Thickness | Nominal Overall Diameter | Nominal Weight | Maximum Conductor Resistance 20°C | Maximum Resistance Unbalance | Characteristic Impedance | Transfer Impedance | Maximum Capacitance | |
---|---|---|---|---|---|---|---|---|---|
@100MHz | f≤30MHz | core to core | Core to screen | ||||||
AWG | mm | mm | kg/km | Ω/km | Ω/km | Ω | mΩ/m | pF/m | pF/m |
22 | 1.2 | 7.25 | 81 | 54.4 | 1.1 | 100+/-5 | 200 | 65 | 100 |
FRL-Cat5E-4P22A
Nominal Cross Sectional Area |
Nominal Sheath Thickness | Nominal Overall Diameter | Nominal Weight | Maximum Conductor Resistance 20°C | Maximum Resistance Unbalance | Characteristic Impedance | Transfer Impedance | Maximum Capacitance | |
---|---|---|---|---|---|---|---|---|---|
@100MHz | f≤30MHz | core to core | Core to screen | ||||||
AWG | mm | mm | kg/km | Ω/km | Ω/km | Ω | mΩ/m | pF/m | pF/m |
22 | 1.2 | 12.6 | 174 | 54.4 | 1.1 | 100+/-5 | 200 | 65 | 100 |