PE Insulated Air Core/Jelly Filled Paired Railway Signalling Cables (RF 0.3)
Application:
The cables are designed to give good protection to the cable cores against inductive interference (RF=0.3). The cables are used for outdoor signaling equipment.
Standards:
RENFE E.T. 03.365.051.6
Construction:
Conductors: Solid annealed bare copper 0.9/1.4mm as per ASTM B-3/class 1 of IEC 60228
Insulation: Solid polyethylene as per ASTM D 1248/IEC 60708
Twisted Pairs: Two insulated conductors are twisted into pairs with varying lays to minimize crosstalk
Cable Core Assembly: The cores are cabled together in concentric layers to form the cable core. Units are identified by colour coded binders
Core Filling (optional): The cable core interstices can be filled with petroleum jelly to avoid longitudinal water penetration inside the cable
Core Wrapping: One or more non-hygroscopic polyester tapes are helically or longitudinally laid with an overlap
Moisture Barrier (optional): An optional copolymer coated aluminium tape of 0.2mm is applied longitudinally with an overlap
Bedding:PE or LSZH
Electrostatic Screen:
Corrugated copper tape of 0.12mm is applied longitudinally with overlap
Electrostatic Armour:
Two high permeability steel tapes of 0.5mm are helically applied with gap. The outer tape will cover the gap left by the inner one
Sheath: PVC or LSZH
Ripcord: Nylon ripcord may be placed parallel to the cores to facilitate sheath removal
Electrical Properties:
Nominal Conductor Diameter | mm | 0.9 | 1.4 |
---|---|---|---|
Conductor Size | mm2 | 0.636 | 1.539 |
Maximum Conductor Resistance @20°C | Ω/km | 28 | 12.1 |
Minimum Insulation Resistance @500V DC | MΩ.km | 35000 | 5000 |
Reduction Factor Rk (50Hz) Induced Voltage Em 100V/Km | 0.3 | 0.3 | |
Induced Voltage Em 500V/Km | 0.5 | 0.5 | |
Maximum Resistance Unbalance | % | 2.5 | 2.5 |
Maximum Mutual Capacitance @0.8KHz | nF/km | 59 | 64 |
Maximum Capacitance Unbalance @1KHz pair-to-pair | pF/500m | 275 | 275 |
Maximum Capacitance Unbalance @1KHz pair-to-ground | pF/500m | 1200 | 1200 |
Maximum Average Attenuation @1KHz | dB/km | 0.7 | 0.46 |
Maximum Average Attenuation @10KHz | dB/km | 1.6 | 0.85 |
Maximum Average Attenuation @20KHz | dB/km | 2.1 | 1.3 |
Dielectric Strength Conductor to Conductor 1 min | V DC | 1500 | 1500 |
Conductor to Screen 1min | V DC | 2000 | 2000 |
Dielectric Strength Conductor to Conductor 3secs | V DC | 3000 | 3000 |
Conductor to Screen 3secs | V DC | 4500 | 4500 |
Nominal Insulation Thickness | mm | 0.45 | 0.65 |
Nominal Insulated Conductor Diameter | mm | 1.8 | 2.7 |
Mechanical and Thermal Properties:
Temperature range during operation (fixed state): -30°C – +70°C
Temperature range during installation (mobile state): -20°C – +50°C
Minimum bending radius: 15 x Overall Diameter
Colour Code:
Position | Number of pairs | |||||||||
---|---|---|---|---|---|---|---|---|---|---|
1(Pilot) | 2(Direct) | 3 | 4 | 5 | ||||||
Centre | BLACK | NATURAL | BLUE | NATURAL | YELLOW | NATURAL | RED | NATURAL | ||
Layers | BLACK | NATURAL | BLUE | NATURAL | YELLOW | NATURAL | RED | NATURAL | GREEN | NATURAL |
Dimensions And Weight:
Cable Code | Number of Pairs | Nominal Bedding/ Sheath Thickness mm |
Nominal Overall Diameter mm |
Nominal Weight kg/km |
---|---|---|---|---|
0.9mm Conductor, 1.8mm Insulated Wire | ||||
TP365-2Y2Y(CTS)2Y(DSTA)Y2P09-RF03 | 2 | 1.5/1.6 | 18.3 | 1300 |
TP365-2Y2Y(CTS)2Y(DSTA)Y6P09-RF03 | 6 | 1.5/1.6 | 21.7 | 1425 |
TP365-2Y2Y(CTS)2Y(DSTA)Y10P09-RF03 | 10 | 1.5/1.6 | 25.2 | 1650 |
TP365-2Y2Y(CTS)2Y(DSTA)Y14P09-RF03 | 14 | 1.5/1.6 | 26.7 | 1800 |
TP365-2Y2Y(CTS)2Y(DSTA)Y20P09-RF03 | 20 | 1.5/1.6 | 29.2 | 2275 |
TP365-2Y2Y(CTS)2Y(DSTA)Y28P09-RF03 | 28 | 1.6/1.8 | 32.3 | 2450 |
TP365-2Y2Y(CTS)2Y(DSTA)Y38P09-RF03 | 38 | 1.7/1.8 | 36.0 | 2895 |
TP365-2Y2Y(CTS)2Y(DSTA)Y54P09-RF03 | 54 | 1.7/1.8 | 40.5 | 3275 |
TP365-2Y2Y(CTS)2Y(DSTA)Y74P09-RF03 | 74 | 1.8/2.0 | 45.6 | 3775 |
TP365-2Y2Y(CTS)2Y(DSTA)Y96P09-RF03 | 96 | 1.9/2.0 | 49.8 | 4275 |
1.4mm Conductor, 2.7mm Insulated Wire | ||||
TP365-2Y2Y(CTS)2Y(DSTA)Y2P14-RF03 | 2 | 1.5/1.6 | 20.2 | 1615 |
TP365-2Y2Y(CTS)2Y(DSTA)Y6P14-RF03 | 6 | 1.5/1.6 | 25.7 | 1775 |
TP365-2Y2Y(CTS)2Y(DSTA)Y10P14-RF03 | 10 | 1.6/1.8 | 30.8 | 2200 |
TP365-2Y2Y(CTS)2Y(DSTA)Y14P14-RF03 | 14 | 1.6/1.8 | 32.8 | 2525 |
TP365-2Y2Y(CTS)2Y(DSTA)Y20P14-RF03 | 20 | 1.7/1.8 | 36.5 | 2975 |
TP365-2Y2Y(CTS)2Y(DSTA)Y28P14-RF03 | 28 | 1.7/1.8 | 40.5 | 3150 |
TP365-2Y2Y(CTS)2Y(DSTA)Y38P14-RF03 | 38 | 1.8/2.0 | 45.6 | 3695 |
TP365-2Y2Y(CTS)2Y(DSTA)Y58P14-RF03 | 58 | 2.0/2.2 | 52.3 | 3975 |
TP365-2Y2Y(CTS)2Y(DSTA)Y74P14-RF03 | 74 | 2.1/2.2 | 59.1 | 4475 |
TP365-2Y2Y(CTS)2Y(DSTA)Y96P14-RF03 | 96 | 2.2/2.3 | 66.0 | 4975 |