HOMEPRODUCTS Telephone Cable

 

PE Insulated ISDN Basic Access Air Core Cables

 

 

Application:

The cables are used as basic access for ISDN services in central office wiring and cabling for ISDN basic access installation.

Standards:

ER.f5.058

Construction:

Telephone CablesTelephone Cables

Conductors: Solid annealed bare copper sized 0.5/0.6mm as per ASTM B-3/IEC 60228 class 1

Insulation: Solid polyethylene as per ASTM D 1248/IEC 60708

Twisted Pairs: Insulated conductors are twisted into pairs with varying lays to minimize crosstalk

Cable Core Assembly: The pairs are cabled together in layers of 12, 13 & 25 pair unit to form the cable core. Units are identified by colour coded binders

Core Wrapping: One or more non-hygroscopic polyester tapes are helically or longitudinally laid with an overlap

Sheath: PVC/LSZH

Ripcord (optional):

Nylon ripcord may be placed parallel to the cores to facilitate sheath removal

Electrical Properties:

Nominal Conductor Diameter mm 0.5 0.6
Conductor Gauge Size AWG 24 -
Conductor Size mm2 0.196 0.283
Maximum Conductor Resistance @20°C Ω/km 91 63
Minimum Insulation Resistance @500V DC MΩ.km 16000 16000
Maximum Resistance Unbalance % 2.5 2.5
Average Mutual Capacitance nF/km 52 52
Maximum Capacitance Unbalance @1KHz pair-to-pair pF/km 260 260
Maximum Capacitance Unbalance @1KHz pair-to-ground pF/km 2625 2625
Maximum Average Attenuation @20KHz dB/km 4.9 3.9
Maximum Average Attenuation @40KHz dB/km 6.2 4.8
Maximum Average Attenuation @60KHz dB/km 7.0 5.6
Maximum Average Attenuation @80KHz dB/km 7.7 6.0
Maximum AverageAttenuation @100KHz dB/km 7.9 6.3
Minimum ELFEXT pair-to-pair @20KHz dB 56 56
Minimum ELFEXT pair-to-pair @40KHz dB 52 52
Minimum ELFEXT pair-to-pair @60KHz dB 50 50
Minimum ELFEXT pair-to-pair @80KHz dB 49 49
Minimum ELFEXTpair-to-pair @100KHz dB 48 48
Minimum NEXT pair-to-pair @20KHz dB 61 61
Minimum NEXT pair-to-pair @40KHz dB 57 57
Minimum NEXT pair-to-pair @60KHz dB 55 55
Minimum NEXT pair-to-pair @80KHz dB 54 54
Minimum NEXTpair-to-pair @100KHz dB 51 51
Dielectric Strength Conductor to Conductor 3secs V DC 3600 3600
Nominal Insulation Thickness mm 0.2 0.25
Nominal Insulated Conductor Diameter mm 0.9 1.1

Mechanical and Thermal Properties:

Temperature range during operation (fixed state): -30°C – +70°C

Temperature range during installation (mobile state): -20°C – +50°C

Minimum bending radius: 15 x Overall Diameter

Colour Code:

Standard colour code is per BT CW 110J given in Colour Code Chart.

Dimensions And Weight:

Cable Code Number of Pairs Nominal Sheath Thickness
mm
Nominal Overall Diameter
mm
Nominal Weight kg/km
0.5mm Conductor, 0.9mm Insulated Wire
TP58-2Y(St)Y2P05-ISDN-B 2 0.8 4.5 23.0
TP58-2Y(St)Y4P05-ISDN-B 4 0.8 5.0 33.5
0.6mm Conductor, 1.1mm Insulated Wire
TP58-2Y(St)Y2P06-ISDN-B 2 1.0 5.5 30.0
TP58-2Y(St)Y4P06-ISDN-B 4 1.0 6.0 45.0