PVC Insulated & PVC Sheathed Installation Cables to DIN VDE 0815/DIN 57815
J-YY…2X0.6 Bd
Application:
The installation cables are used for telephone and signal transmission for permanent surface or concealed installation in dry and damp rooms, on or under plaster, and on external walls.
Standards:
DIN VDE 0815/DIN 57815
Construction:
Conductors: Solid annealed bare copper sized 0.6mm as per VDE 0295/IEC 60228 Class 1
Insulation: PVC YI1 type to DIN VDE 0207-2
Cabling Element: Star Quads
Cable Core Assembly: Each 4 wires are stranded into a star quad, the quads are stranded to units and the units are stranded to form the core
Core Wrapping: One or more non-hygroscopic polyester tapes are helically or longitudinally laid with an overlap prior to sheathing
Screen: Laminated aluminium foil is fully enclosing the core with an overlap
Sheath: PVC YM1 type to DIN VDE 0207 part 5
Ripcord: Nylon ripcord may be placed parallel to the cores to facilitate sheath removal
Drain Wire: Tinned drain wire applied longitudinally to provide continuity of the screen
Type Codes
J Installation Cable Y Polyvinyl Chloride (PVC) Bd Unit stranding.
Electrical Properties:
Nominal Conductor Diameter | mm | 0.6 |
---|---|---|
VDE CODE | J-YY | |
Conductor Size | mm2 | 0.283 |
Maximum Conductor Resistance @20°C | Ω/km | 63 |
Minimum Insulation Resistance @500V DC @20°C | MΩ.km | 100 |
Maximum Mutual Capacitance @0.8KHz | nF/km | 100 |
Maximum Capacitance Unbalance @0.8KHz | ||
K1 max | pF/100m | 300 |
K9-K12 max | pF/100m | 100 |
Maximum Loop Resistance @20°C | Ω/km | 130 |
Maximum Average Attenuation @0.8KHz | dB/km | 1.7 |
Maximum Working Voltage Peak Value | V | 300 |
Nominal Insulation Thickness | mm | 0.2 |
Nominal Insulated Conductor Diameter | mm | 1.0 |
Mechanical and Thermal Properties:
Temperature range during operation (fixed state): -30°C – +70°C
Temperature range during installation (mobile state): -20°C – +50°C
Minimum bending radius: 7.5 x Overall Diameter
Colour Code:
Quads
The single core is identified by black ring markings:
Side Circuit 1 | a-wire | without marking |
---|---|---|
b-wire | 1 mark distance 17mm | |
Side Circuit 2 | a-wire | 2 marks distance 34mm |
b-wire | 2 marks distance 17mm |
Subunits:
Basic colours for the wire insulation of the 5 star quads of a basic unit:
Quad 1 Red | Quad 2 Green | |
Quad 3 Grey | Quad 4 Yellow | Quad 5 White |
The tracer units are coded with a red helix, all other units by a white binder
Dimensions And Weight:
VDE CODE: J-YY…x2x 0.6 Bd
Cable Code | Number of Pairs |
Nominal Insulation
Thickness mm |
Nominal Sheath
Thickness mm |
Nominal Overall
Diameter mm |
Nominal
Weight kg/km |
---|---|---|---|---|---|
0.6mm Conductor, 1.0mm Insulted Wires | |||||
TP815J-YY-Bd-2P06 | 2 | 0.2 | 1.0 | 4.5 | 34 |
TP815J-YY-Bd-4P06 | 4 | 0.2 | 1.0 | 6.5 | 59 |
TP815J-YY-Bd-6P06 | 6 | 0.2 | 1.0 | 7.0 | 74 |
TP815J-YY-Bd-10P06 | 10 | 0.2 | 1.0 | 8.5 | 111 |
TP815J-YY-Bd-16P06 | 16 | 0.2 | 1.0 | 10.0 | 160 |
TP815J-YY-Bd-20P06 | 20 | 0.2 | 1.0 | 11.0 | 200 |
TP815J-YY-Bd-24P06 | 24 | 0.2 | 1.0 | 11.5 | 224 |
TP815J-YY-Bd-30P06 | 30 | 0.2 | 1.2 | 13.0 | 284 |
TP815J-YY-Bd-40P06 | 40 | 0.2 | 1.2 | 15.0 | 364 |
TP815J-YY-Bd-50P06 | 50 | 0.2 | 1.2 | 16.5 | 451 |
TP815J-YY-Bd-60P06 | 60 | 0.2 | 1.4 | 17.5 | 529 |
TP815J-YY-Bd-80P06 | 80 | 0.2 | 1.4 | 20.3 | 700 |
TP815J-YY-Bd-100P06 | 100 | 0.2 | 1.4 | 22.3 | 850 |