PE Insulated & PE Sheathed Non Metallic Reinforced Drop Wires to RUS (REA) PE-7

 

 

Application

The drop wires are one or two pair aerial service wires designed for use in extending telephone service to subscriber premises from the cable terminal.

Standards

RUS (REA) PE-7

Construction

Telephone CablesTelephone Cables

Conductors: Solid annealed bare copper 0.5/0.8mm as per ASTM B-3/IEC 60228 Class 1

Insulation: Solid polyethylene as per ASTM D 1248/IEC 60708

Cable Core Assembly & Core Wrapping: Individual conductors are twisted into pairs and wrapped with PETP tape

Strength Member: Aramid yarn as non-metallic strength member is placed inside the sheath to provide longitudinal strength

Sheath: PE is extruded over the core to provide protection against mechanical damage, degradation by sunlight and water ingress

Ripcord: A ripcord made of polyamide is placed parallel to the core to facilitate sheath removal

Electrical Properties:

Conductor Diameter mm 0.5 0.8
Conductor Gauge Size AWG 24 20
Maximum Conductor Resistance @20°C Ω/km / Ω/mile 91/145.78 34.6/55.72
Minimum Insulation Resistance @500V DC MΩ.km / MΩ.mile 10000/6214 10000/6214
Maximum Resistance Unbalance % 2 2
Average Mutual Capacitance @1000Hz nF/km / nF/kft 55/16.8 55/16.8
Maximum Capacitance Unbalance pair-to-pair pF/km / pF/kft 300/91 300/91
Maximum Capacitance Unbalance pair-to-ground pF/km / pF/kft 1000/303.4 1000/303.4
Impedance @0.8KHz Ω/km / Ω/mile 600/965.6 600/965.6
Impedance @64KHz Ω/km / Ω/mile 125/201.2 125/201.2
Impedance @772KHz Ω/km / Ω/mile 100/160.9 100/160.9
Maximum Average Attenuation @0.8KHz Ω/km / Ω/mile 1.5/2.4 1.5/2.4
Maximum Average Attenuation @64KHz Ω/km / Ω/mile 8.0/12.87 8.0/12.87
Maximum Average Attenuation @772KHz Ω/km / Ω/mile 18/28.97 18/28.97
Dielectric Strength 1min V 1000DC/1500AC 1000DC/1500AC

Mechanical and Thermal Properties:

Temperature range during operation (fixed state): -30°C – +70°C

Temperature range during installation (mobile state): -20°C – +50°C

Minimum bending radius: 10 x Overall Diameter

Color Code:

  A wire B wire
1 PR White Blue
1 PR Yellow Black

Dimensions And Weight:

Cable Code Number of Pairs Insulation Thickness mm/inch Sheath Thickness
mm/inch
Nominal Overall
Diameter
mm/inch
Nominal Weight
kg/km / lbs/kft
0.5mm Conductor, 0.9mm Insulated Wire
TP7-2Y2Y-2P05-SS-A 2 0.2/0.0079 1.2/0.047 5.0/0.197 26.2/17.6
0.8mm Conductor, 1.36mm Insulated Wire
TP7-2Y2Y-1P08-SS-A 1 0.28/0.0110 1.2/0.047 5.3/0.209 26.6/17.9