HOMEPRODUCTS Telephone Cable

 

PE Insulated Category 3 UTP/FTP Cables

 

 

Application:

The cables are designed for medium frequency data or telephone systems, suitable for indoor or outdoor insulations.

Standards:

TIA/EIA-568B

IEC 61156-4

UL-444

ANSI/ICEA S-80-576

Construction:

UTP/FTP CablesUTP/FTP Cables

Conductors: Solid annealed bare copper sized 0.5mm (24 AWG) as per ASTM-B3/class 1 of IEC 60228

Insulation: Solid polyethylene as per ASTM D 1248/IEC 60708

Twisted Pairs: Insulated conductors are twisted into pairs with varying lay length to minimize crosstalk

Cable Core Assembly: The 50-pair cable is composed of 4 units having 12 or 13 pairs each. All other cables are composed of 25-pair units. Units are identified by colour coded binders

Core Wrapping: Non-hygroscopic dielectric tape fully enclosing the core with an overlap

Screen (optional): An optional Aluminium/Polyester tape placed in contact with solid copper drain wire may be provided as an option

Sheath: PVC or LSZH

Ripcord: Nylon ripcord may be placed parallel to the cores to facilitate sheath removal

Electrical Properties:

Nominal Conductor Diameter mm 0.5
Maximum DC Resistance Ω/100m 9.38
Maximum Resistance Unbalance % 5
Maximum Capacitance Unbalance pair-to-ground @1KHz pF/100m 330
Minimum Worst Pair Structural Return Loss (SRL):    
       Up to 10 MHz dB 12
       Between 10 and 16 MHz dB 10
Impedance @1-16 MHz 85 - 115
Maximum Attenuation at 20°C    
       @64KHz dB/100m 0.9
       @256KHz dB/100m 1.3
       @512KHz dB/100m 1.8
       @772KHz dB/100m 2.2
       @1MHz dB/100m 2.6
       @4MHz dB/100m 5.6
       @8MHz dB/100m 8.5
       @10MHz dB/100m 9.7
       @16MHz dB/100m 13.1
Minimum Worst pair-to-pair NEXT Loss    
       @772KHz dB 43
       @1MHz dB 41
       @4MHz dB 32
       @8MHz dB 28
       @10MHz dB 26
       @16MHz dB 23
Minimum Relative Velocity of Propagation @10MHz dB 0.585

Mechanical and Thermal Properties:

Temperature range during operation (fixed state): -30°C – +70°C

Temperature range during installation (mobile state): -20°C – +50°C

Minimum bending radius: 10 x Overall Diameter (unarmoured cable);15 x Overall Diameter (armoured cables)

Colour Code:

Standard Colour Code is per TIA/EIA 568B or ICEA S-80-576 as given in Colour Code Chart.

Dimensions And Weight:

PE INSULATED CATEGORY 3 UTP CABLES

Cable Code Number of Pairs Nominal Sheath Thickness
mm
Nominal Overall Diameter
mm
Nominal Weight
kg/km
0.5mm Conductor, 0.9mm Insulated Wire, UTP, PVC Sheathed, Indoor
TP568-2YY-10P05-UTPC3 10 0.9 9.5 77
TP568-2YY-25P05-UTPC3 25 0.9 12.5 155
TP568-2YY-50P05-UTPC3 50 1.0 17.0 260
TP568-2YY-100P05-UTPC3 100 1.1 21.5 530
TP568-2YY-200P05-UTPC3 200 1.2 29.5 1100
TP568-2YY-300P05-UTPC3 300 1.3 33.5 1550
0.5mm Conductor, 0.9mm Insulated Wire, UTP, LSZH Sheathed, Indoor & Outdoor
TP568-2YH-10P05-UTPC3 10 0.9 10.0 80
TP568-2YH-25P05-UTPC3 25 0.9 14.0 150
TP568-2YH-50P05-UTPC3 50 1.1 16.5 280
TP568-2YH-100P05-UTPC3 100 1.4 21.5 530
TP568-2YH-200P05-UTPC3 200 1.7 30.0 900
TP568-2YH-300P05-UTPC3 300 1.7 36.0 1300
0.5mm Conductor, 0.9mm Insulated Wire, UTP, PE Sheathed, Outdoor
TP568-2Y2Y-10P05-UTPC3 10 0.9 9.5 80
TP568-2Y2Y-25P05-UTPC3 25 0.9 13.0 150
TP568-2Y2Y-50P05-UTPC3 50 1.0 16.0 280
TP568-2Y2Y-100P05-UTPC3 100 1.1 21.5 550
TP568-2Y2Y-200P05-UTPC3 200 1.2 28.5 1050
TP568-2Y2Y-300P05-UTPC3 300 1.3 34.5 1550

PE INSULATED CATEGORY 3 FTP CABLES

Cable Code Number of Pairs Nominal Sheath Thickness
mm
Nominal Overall Diameter
mm
Nominal Weight
kg/km
0.5mm Conductor, 0.9mm Insulated Wire, FTP, PVC Sheathed, Indoor
TP568-2Y(St)Y-10P05-FTPC3 10 0.9 10.0 85
TP568-2Y(St)Y-25P05-FTPC3 25 0.9 13.5 170
TP568-2Y(St)Y-50P05-FTPC3 50 1.0 17.0 300
TP568-2Y(St)Y-100P05-FTPC3 100 1.1 22.0 570
TP568-2Y(St)Y-200P05-FTPC3 200 1.2 30.0 1120
TP568-2Y(St)Y-300P05-FTPC3 300 1.3 36.6 1630
0.5mm Conductor, 0.9mm Insulated Wire, FTP, LSZH Sheathed, Indoor& Outdoor
TP568-2Y(St)H-25P05-FTPC3 25 0.9 14.0 170
TP568-2Y(St)H-50P05-FTPC3 50 1.0 17.5 300
TP568-2Y(St)H-100P05-FTPC3 100 1.2 23.0 580
TP568-2Y(St)H-200P05-FTPC3 200 1.6 32.0 1120
TP568-2Y(St)H-300P05-FTPC3 300 1.6 35.0 1320
0.5mm Conductor, 0.9mm Insulated Wire, FTP, PE Sheathed, Outdoor
TP568-2Y(St)2Y-10P05-FTPC3 10 0.9 11.0 85
TP568-2Y(St)2Y-25P05-FTPC3 25 0.9 13.5 170
TP568-2Y(St)2Y-50P05-FTPC3 50 1.0 16.5 300
TP568-2Y(St)2Y-100P05-FTPC3 100 1.1 22.6 570
TP568-2Y(St)2Y-200P05-FTPC3 200 1.2 31.0 1070
TP568-2Y(St)2Y-300P05-FTPC3 300 1.3 35.5 1570