Application:

The cables are designed for XDSL transmission system. The cables are characterized by guaranteed data speeds up to 40MHz.

Standards:

ER.f5.113

Construction:

Telephone CablesTelephone Cables

Conductors:Solid annealed bare copper sized 0.5mm as per ASTM B-3/IEC 60228 Class1

Insulation: Solid polyethylene as per ASTM D 1248/IEC 60708

Twisted Pairs: Insulated conductors are twisted into pairs with varying lays to minimize crosstalk

Cable Core Assembly: The pairs are cabled together in layers of 12, 13 & 25 pair unit to form the cable core. Units are identified by colour coded binders.

Core Wrapping: One or more non-hygroscopic polyester tapes are helically or longitudinally laid with an overlap

Screen: An aluminium polyster foil is applied longitudinally with an overlap

Sheath: Black low density polyethylene as per BS 6234/IEC 60708

Ripcord: Nylon ripcord may be placed parallel to the cores to facilitate sheath removal

Electrical Properties:

Conductor Diameter mm 0.5
Maximum Conductor Resistance @20°C Ω/km 91
Minimum Insulation Resistance @500V DC MΩ.km 20000
Maximum Resistance Unbalance % 2
Average Mutual Capacitance nF/km 52
Maximum Capacitance Unbalance @1KHz pair-to-pair pF/500m 45
Maximum Capacitance Unbalance @1KHz pair-to-ground pF/500m 400
Impedance @0.3 – 1MHz 100+/- 20
Impedance @1 – 40MHz 100+/- 15
Maximum Average Attenuation @0.1MHz dB/km 0.81
Maximum Average Attenuation @0.3MHz dB/km 1.15
Maximum Average Attenuation @0.6MHz dB/km 1.65
Maximum Average Attenuation @1MHz dB/km 2.1
Maximum Average Attenuation @4MHz dB/km 4.3
Maximum Average Attenuation @10MHz dB/km 6.6
Maximum Average Attenuation @16MHz dB/km 8.2
Maximum Average Attenuation @20MHz dB/km 9.2
Maximum Average Attenuation @31.25MHz dB/km 11.8
Maximum Average Attenuation @40MHz dB/km 13.9
Minimum Return Loss @1-20MHz dB/100m 23
Minimum Return Loss @20-40MHz dB/km 23-10log (f/20)
Minimum ELFEXT pair-to-pair @0.16MHz dB 69
Minimum ELFEXT pair-to-pair @1MHz dB 55
Minimum ELFEXT pair-to-pair @20MHz dB 29
Minimum ELFEXT pair-to-pair @40MHz dB 23
Minimum NEXT pair-to-pair @0.16MHz dB 68
Minimum NEXT pair-to-pair @1MHz dB 59
Minimum NEXT pair-to-pair @20MHz dB 39
Minimum NEXT pair-to-pair @40MHz dB 35
Dielectric Strength dB  
Conductor to Conductor 3secs V DC 3000
Conductor to Screen 3secs V DC 5000

Mechanical and Thermal Properties:

Temperature range during operation (fixed state): -30°C – +70°C

Temperature range during installation (mobile state): -20°C – +50°C

Minimum bending radius: 10 x Overall Diameter

Colour Code:

Standard colour code is per ANSI/ICEA S-80-576 given in Colour Code Chart.

Dimensions And Weight:

Cable Code Number
of
Pairs/Quads
Nominal Insulation
Thickness
mm
Nominal Sheath
Thickness
mm
Nominal Overall
Diameter
mm
Nominal Weight
kg/km
TP113-2Y(St)Y-26P05-XDSL 26 0.2 0.9 18.5 265
TP113-2Y(St)Y-51P05-XDSL 51 0.2 1.0 24.2 460
TP113-2Y(St)Y-101P05-XDSL 101 0.2 1.1 31.5 790
TP113-2Y(St)Y-202P05-XDSL 202 0.2 1.2 41.5 1415