HOMEPRODUCTSTUNNEL CABLE

 

TUNNEL CABLES

NSHCGEöU KON+ST+UL

 

 

 

 

Application:

It is used for connection of mobile machines with very high mechanical load, especially in mines for coal cutting and loading machines as well as for supplying appliances and auxiliary and auxiliary electrical circuits. Concentric phase monitoring screen and overall concentric earth conductor facilitate in connection with a suitable monitoring equipment monitoring of the cable from standpoint of insulation faults and damages that are caused by external effects.

STANDARDS:

construction

DIN VDE 0250-812

General Requirements

DIN VDE 0250-1

Guide Use

DIN VDE 0298-3

Electrical Tests

DIN VDE 0472-501, 503, 508

Non-Electrical Tests

DIN VDE 0472-401. 402,602,303, 615

Under Fire Condition Tests

DIN VDE 0472-803, 804

Flame Retardant

VDE 0482-332-1-2,DIN EN 60332-1-2,IEC 60332-1

Oil Resistant

HD/EN/IEC 60811-2-1.,DIN VDE0473-811-2-1

CABLE CONSTRUCTION:

Power Cores
conductor Tinned copper conductor DIN VDE 0295 class 5
Insulation Based on 3Gl3-EPR rubber and semi rubber compound
Control Cores+Monitoring Pe Core(S)
conductor

Tinned copper conductor DIN VDE 0295 class 5

Insulation

3Gl3 type EPR compound and semi conductive rubber compound

Lay Up

Three power cores laid up with the protective earth conductors split into three in the outer interstices. If there are 3 control cores. the monitoring core is concentrically wrapped over insulation of control cores.

Inner Sheath

GM1b type EPR compound

Screen

Flexible- pliable armour in helix of tinned copper and galvanised steel wires.

Outer Sheath

Heavy-duty  elastomer  5GM5  type  rubber  compound Yellow  or
Red.

Technical Characteristics:

Rated Voltage

0.6 / 1 KV

Max.Permissible Operating Voltage AC

0.7 / 1.2 KV

Max.Permissible Operating Voltage DC

0.9 / 1.8 KV

AC Test Voltage

3KV

AC Test Voltage(For control cores)

2KV

Min. 011otance with S-Type Directional Changes

20×D

Current Carrying Capacities

According to DIN VDE 0298-4

Working Temperature
Fixed

-40°C-+80°C

Mobile

-25°C-+80°C

Max.Tensile Load Of cable

15N/mm²

Dimensions And Weight :

Cross Section
(mm²)
Overall Diameter
min-max (mm)
Appro. Weight (kg/km)

3×16/16 KON + (2x1.5 St+1.5 ÜL)

35-38

2150

3×25/16 KON + (2x1.5 St+1.5 ÜL)

41-46

3000

3×35/16 KON + (2x1.5 St+1.5 ÜL)

42-47

3400

3×70/35 KON + (2x1.5 St+1.5 ÜL)

46-51

4300

3×70/35 KON + (2x1.5 St+1.5 ÜL)

52-56

5600

3×95/50 KON + (2x1.5 St+1.5 ÜL)

58-62

7100

3x25/16 KON+3x(1.5 ST KON/1.5 ÜL KON)

42-46

3130

3x35/16 KON+3x(1.5 ST KON/1.5 ÜL KON)

43-47

3610

3x50/35 KON+3x(1.5 ST KON/1.5 ÜL KON)

49-53

4580

3x70/35 KON+3x(1.5 ST KON/1.5 ÜL KON)

52-56

5920

3x95/50 KON+3x(1.5 ST KON/1.5 ÜL KON)

60-64

7400