Windmill Cables
EPR/HFXLEVA Medium Voltage Torsion Resistant Cable
Application:
These cables having torsion resistant, good bending and halogen free are specifically designed for the torsion applications in wind turbines, suitable for transmit energy from the generator to the transformer, which is usually located at the base of the tower.
Standards:
IEC 60502
Construction:
Conductor:Stranded tinned copper, class 5/class 6 according to IEC 60228.
Insulation: EPR.
Sheath: HFXLEVA.
Technical Data:
Rated Voltage U0/U (Um):1.8/3kV
Operating Temperatures:-40℃~+125℃
Minimum Bending Radius:6×OD
Torsion Application:+/-180°/m
Flame Retardant:IEC 60332-3
Halogen Free:IEC 60754
Corrosive Gases:IEC 60754
Smoke Density:IEC 61034
Oil Resistant:Yes
Ozone Resistant:Yes
UV Resistant:Yes
Cold Resistant:CSA C 22.2
Dimensions and Weight:
1.8/3kV
Construction | Nominal Overall Diameter | Nominal Weight |
---|---|---|
No. of cores×mm² | mm | kg/km |
1×25 | 12.9 | 516 |
1×35 | 14.3 | 670 |
1×50 | 16.5 | 840 |
1×70 | 18.6 | 1112 |
1×95 | 21.6 | 1520 |
1×120 | 23.7 | 1880 |
1×150 | 26.2 | 2513 |
1×185 | 29.9 | 3272 |
1×240 | 32.1 | 3534 |
1×300 | 34.5 | 4020 |
1×400 | 39.3 | 5640 |