Windmill Cables
H07BN4-F & UL/CSA 600V 90℃Torsion Resistant Cable
Application:
These cables with increased tolerance to torsion application, improved behaviour against abrasion and extended temperature, UV and ozone resistant are specially designed for wind turbines.
Standards:
HD 22.12
UL/CSA 22.2
UL 758
Construction:
Conductor: Flexible annealed bare copper, class 5 according to IEC/EN 60228.
Insulation: Special cross-linked EI7 rubber for high temperatures (EPDM class 28). Special thermoset EPR for
high temperature can be offered upon request.
Sheath: High mechanical performance special cross-linked EM7 rubber (CPE class 42). Special thermoset CPE
improved for low temperature behaviour (-40℃) can be offered upon request.
Technical Data:
Rated Voltage Uo/U (Um):600V
Operating Temperatures:-40℃~+90℃
Minimum Bending Radius :fixed: 4×OD; flexing: 6×OD
Torsion Application:+/-150°/m
Maximum Permissible Tensile Load:15 N/mm²
Short-circuit Temperature:250℃
Flame Retardant:EN 50265-1/EN 50265-2-1/IEC 60332-1
Oil Resistant:Yes
Ozone Resistant:Yes
UV Resistant:Yes
Water Resistant:Yes
Impact Resistant:Yes
Dimensions and Weight:
Construction | Nominal Overall Diameter | Nominal Weight |
---|---|---|
No. of cores×mm² | mm | kg/km |
1×120(4/0AWG) | 25.5 | 1540 |
1×150(250MCM) | 28.8 | 1810 |
1×185(350MCM) | 31.4 | 2210 |
1×240(450MCM) | 33.8 | 2750 |
1×300(550MCM) | 37.7 | 3520 |
1×400(750MCM) | 41.4 | 4510 |
1×50(1 AWG) | 18.7 | 730 |
1×95(3/0 AWG) | 23.0 | 1220 |
3×120(4/0 AWG) | 56.0 | 5200 |
3×150(250MCM) | 61.5 | 6400 |
3×240(450MCM) | 72.0 | 9780 |
3×25(4 AWG) | 30.0 | 1420 |
3×35(2 AWG) | 35.3 | 1850 |
3×50(1 AWG) | 39.8 | 2480 |
3×70(2/0 AWG) | 43.8 | 3180 |
3×95(3/0 AWG) | 49.0 | 4260 |
4G50(1 AWG) | 42.5 | 3150 |
4G70(2/0 AWG) | 48.2 | 4240 |
4G95(3/0 AWG) | 53.5 | 5480 |
G: with green-yellow earth core
×: without green-yellow earth core