HOMEPRODUCTS WINDMILL CABLE

 

 

Windmill Cables

I-V(ZN)H11Y Fibre Optic Breakout Cable

 

 

 

Application

These cables are designed for wind turbine control or LAN backbone, suitable for indoor installation or outdoor installation in ducts.

Standards

DIN VDE 0888

IEC 60794

Construction

Windmill Cables

Core Type: Tight buffer.

Strain Relief: Aramid yarns.

Break-out Unit Sheath: LSZH.

Central Strength Member: Dielectric Material.

Outer Sheath: PUR.

Technical Data:

Operating Temperatures:-40℃~+70℃

Minimum Bending Radius:20×OD

Torsion Application:+/-180° 500 times/2m; +/-360° 5 times/2m

Dimensions and Weight:

Construction Fibre Type Nominal Overall Diameter Nominal Weight
No. of fibres - mm kg/km
2 Multimode G50/125 7.5 45
2 Multimode G62.5/125 7.5 45
2 Single-Mode E9/125 7.5 45