HOMEPRODUCTS WINDMILL CABLE

 

 

Windmill Cables

NTSCGEWOEU Medium Voltage Torsion Resistant Cable

 

 

 

Application:

These cables are specifically designed for carrying medium voltage energy from the transformer in the nacelle to the bottom of the tower.

Standards:

DIN VDE 0250 Part 813

Construction:

NTSCGEWOEU

Conductor:Stranded tinned copper, class 5 according to DIN VDE 0295/IEC 60228.

Inner Conductor Layer: Semiconductive rubber compound.

Insulation: Heat resistant EPR.

Outer Conductor Layer: Semiconductive rubber compound.

Sheath: Heat and cold resistant special rubber compound based on CM (Chlorinated synthetic rubber) or CR (Chloroprene rubber).

Technical Data:

Rated Voltage U0/U (Um):12/20kV, 18/30kV, 20/35kV

Operating Temperatures:-40℃~+90℃

Minimum Bending Radius:10×OD

Torsion Application :+/100°/m

Maximum Permissible Tensile Load:20N/mm²

Short-circuit Temperature:200℃

Flame Retardant:DIN EN 502652-1/IEC 60332-1

Oil Resistant:Yes

Ozone Resistant:Yes

UV Resistant:Yes

Dimensions and Weight:

12/20kV

Construction Nominal Overall Diameter Nominal Weight
No. of cores×mm² mm kg/km
3×25/25 61.2 4780
3×35/35 65.9 5700
3×50/50 69.5 6630
3×70/70 73.5 7840

18/30kV

Construction Nominal Overall Diameter Nominal Weight
No. of cores×mm² mm kg/km
3×25/25 79.1 7520
3×35/35 80.5 8050
3×50/50 83.1 8920
3×70/70 89.0 10600

20/35kV

Construction Nominal Overall Diameter Nominal Weight
No. of cores×mm² mm kg/km
3×25/25 86.2 8820
3×35/35 90.8 10000
3×50/50 93.0 10830
3×70/70 96.1 12050