HOMEPRODUCTS AIRPORT CABLES

 

PAS (Public Address System)

RS485 Data Cable RE-02Y(St)H 1P18A

RE-02Y(St)H 1P18A (CU/PE/OSCR/LSZH 1×2×18AWG)

 

Applications:

Airprot cables are designed for RS485 data connections. Airprot cable combines low capacitance insulation with one of the highest levels of screening to provide high speed, interference free, data transmission where continued functionality is required during a fire situation.

Standards:

Basic design :EIA/TIA 485

Halogen Free :IEC 60754-1

No corrosive gas emission :IEC 60754-2

Minimum Smoke Emission :IEC 61034-1/2

Reduced Fire Propagation :IEC 60332-3C / NF C 32070-2.2 (C1)

Flame Retardance :IEC 60332-1 / NF C 32-070-2.1 (C2)

Fire Resistance :IEC 60331-23 / NF C 32-070-2.3(CR1)

VOLTAGE RATING:

300/500V

Construction:

RE-02Y(St)H 1P18A (CU/PE/OSCR/LSZH 1×2×18AWG)

Conductors: tinned annealed copper wire, stranded according to IEC(EN) 60228 class 2 or class 5.

Insulation: Solid or foam PE compound

Cabling Elements: Insulated cores are twisted to form pairs with varying lay length to minimize crosstalk.

Overall screen: Aluminum/ polyester tape with tinned copper drain wire.

Fire Barrier: Fireproof Tape.

Outer Sheath: Thermoplastic LSZH compound type LTS3 as per BS 7655-6.1.

Electrical PROPERTIES :

Dielectric test:1000 V r.m.s. for 5’ (core-core)

Impedance:120Ω

Capacitance:45 nF/km conductor to conductor

                      90 nF/km conductor to shield

Physical AND THERMAL PROPERTIES:

Temperature range during operation (fixed state): -30°C – +90°C

Temperature range during installation (mobile state): -20°C – +50°C

Minimum bending radius: 8 × Overall Diameter

CONSTRUCTION PARAMETERS:

RE-02Y(ST)H 1P18A

No.of pair Wire
Gange
Number & Nominal Diameter of Strands Nominal Insulation Thickness Nominal Sheath Thickness Nominal Overall Diameter Approx. Weight
  AWG No/mm mm mm mm kg/km
1 18 7/0.404 1.15 1.2 10.5 100
1 18 16/0.254 1.15 1.2 10.5 100