HOMEPRODUCTS AUTOMOTIVE CABLES

 

Automotive Cable

Germany Standard

Single-core cable

FL2X

 

 

Application:

This PVC insulated single-core cable is used for low voltage electric installations in vehicles.

Cable Construction:

FL2X

Conductor:Cu-ETP1 bare according to DIN EN 13602

Insulation:XLPE

Standard:

ISO 6722 Class C

Technical Parameters:

Operating temperature:–40°C to +125°C

 

CONDUCTOR CONSTRUCTION INSULATION CABLE
NOMINAL CROSS- SECTION NO. AND DIA. OF WIRES DIAMETER
OF CONDUCTOR MAX.
ELECTRICAL
RESISTANCE AT 20°C MAX.
NOMINAL THICKNESS OVERALL DIAMETER MIN. OVERALL DIAMETER MAX. WEIGHT APPROX.
MM2 NO./MM MM MΩ/M MM MM MM KG/KM

1x0.50

16/0.21

1.10

37.1

0.6

2.1

2.3

8

1x0.75

24/0.21

1.30

24.7

0.6

2.35

2.5

11

1x1.00

32/0.21

1.50

18.5

0.6

2.55

2.7

14

1x1.50

30/0.26

1.80

12.7

0.6

2.85

3.0

19

1x2.00

40/0.26

2.00

9.42

0.6

3.15

3.3

24

1x2.50

50/0.26

2.20

7.6

0.7

3.45

3.6

30

1x3.00

60/0.26

2.40

6.15

0.7

3.95

4.1

38

1x4.00

56/0.31

2.80

4.71

0.8

4.20

4.4

48

1x6.00

84/0.31

3.40

3.14

0.8

4.80

5.0

68

Note: Other configurations, sizes, colors and length not specified herein are available upon request.