HOMEPRODUCTS AUTOMOTIVE CABLES

 

Automotive Cable

Germany Standard

FL4G11Y

 

 

Application:

Automotive EVAinsulated ,PURsheathed multi-cores cable is used for ABS braking systems, wiring inside the engine compartment.

Construction:

FL4G11Y

Conductor:cu-ETP1 tinned according to DIN EN 13602

Insulation:Ethylene vinyl acetate (EVA)

Sheath:Polyurethane(PUR)

Standard Compliance:

ISO 6722 Calss C

Technical Parameters:

Operating temperature:–40 °C to +125 °C

 

Conductor Insulation Cable
Nominal Cross- section No. and Dia. of Wires Diameter max. Electrical
Resistance at 20°C max.
Thickness Wall nom. Diameter of Core Sheath Thickness Overall Diameter min. Overall Diameter max. Weight Approx.

mm2

no./mm

mm

mΩ/m

mm

mm

mm

mm

mm

kg/km

2x0.50

16/0.21

1.00

40.10

0.60

2.20

0.85

5.90

6.30

44

2x0.75

40/0.16

1.10

27.10

0.60

2.30

0.90

6.40

6.80

49

2x1.50

30/0.26

1.70

13.70

0.60

2.90

0.90

7.60

8.00

66

3x0.50

16/0.21

1.00

40.10

0.60

2.20

0.80

6.00

6.40

51

3x1.50

30/0.26

1.70

13.70

0.70

2.90

1.10

8.10

8.70

107

Note: Other configurations, sizes, colors and length not specified herein are available upon request