HOMEPRODUCTS AUTOMOTIVE CABLES

 

Automotive Cable

Germany Standard

Single-core cable

FLR14Y

 

 

Application:

This PFA insulated automotive cable is used for cable harnesses,cable with excellent resistance against chemicals,can be used as an alternative to PTFE.

Construction:

FLR14Y

Conductor:Sliver or Nickel plated copper

Insulation:PFA Standard:ISO 6722 Class H

Technical Parameters:

Operating temperature: –80°C to +260°C

 

Conductor Construction Insulation Cable
Nominal Cross- section No. and Dia. of Wires Diameter of Conductor max. Electrical
Resistance at 20°C max.
Nominal Thickness Overall Diameter min. Overall Diameter max. Weight Approx.
mm2 no./mm mm mΩ/m mm mm mm kg/km

1x0.5

19/0.19

1.00

38.2

0.22

1.4

1.60

7

1x0.75

19/0.22

1.20

25.4

0.24

1.7

1.90

10

1x1

19/0.25

1.35

19.1

0.24

1.9

2.10

12

1x1.5

19/0.32

1.70

13

0.24

2.2

2.40

17

1x2.5

19/0.40

2.20

7.8

0.28

2.7

3.00

28

1x4

56/0.30

2.70

4.8

0.32

3.4

3.70

45

Note: Other configurations, sizes, colors and length not specified herein are available upon request.