Heim
Über uns
Produkte
Herunterladen
Technische Lib
Kontakt
Anfrage
Sitemap
Links
 

Alarm u. Audio u. Elektronisches Kabe

Belden gleichwertige Kabel

Koaxial-Kabel

SteuerKabel

LWL Kabel

Flexible Kabel

Instrumentation Kabel

Lan Kabel
EnergieKabel
Bahn-Kabel

Robotik

Rolling Stock Kabel
Gummi u. Kran Kabel
Sicherheit Kabel

Telefon Kabel

Flughafen Kabel

Bus-Kabel

Kabelverschraubungen

Daten Kabel

Heat Detection Kabel
Hochtemperatur-Kabel
Highway Kabel
Marine, Öl, Gas & Petrochemie-Kabel
Special Cables
Spiralkabel
Thermoelement-Kabel
Other Cable
     
  Indoor tight buffer fiber optic cable  
Indoor Used Tight Buffered Fiber
Optical Cable
outdoor multi loose tube fiber optic cable
Outdoor Used Multi Loose Tube
Fiber Optical Cable
 
  Thermocouple Cables 

Thermocouple Cables

Part 2 Type 3 PVC Insulated Individual & Collective Screen Lead SWA PVC Sheathed Thermocouple Cables

Application :
Thermocouple Cables are sensor for measuring temperature, that consists of two dissimilar metals that are joined together at the sensing end. They can be employed as the thermocouple hot junction in addition to serving as the entire wire connection between hot and cold reference junctions.

Types: VX

Conductors: 0.5sqmm class 1 solid

Insulation: PVC (Polyvinyl Chloride)

Screen: IAM (Individual aluminium mylar) & CAM (Collective aluminium mylar)

Bedding: PVC (Polyvinyl Chloride)

Armour/Protection: LC (Lead alloy)

Bedding: PVC (Polyvinyl Chloride)

Armour/Protection: SWA (Single wire armour)

Sheath/Jacket: PVC (Polyvinyl Chloride)

Colour: Blue 

Voltage: 300/500V

Standards: BS4937 International thermocouple reference tables. Extension & compensating cables. Tolerances and identification systems

BS5308 Part 2, Insulated cables, instrumentation, PVC

Part 2 Type 3 PVC Insulated Individual & Collective Screen Lead SWA PVC Sheathed Thermocouple Cables

Size sq
(mm)

Stranding
(mm)

RT of Insulation
(mm)
Diameter over Bedding
(mm)
Diameter of Armour Wire

Diameter over Armour
(mm)

RT of Outer Sheath
(mm)

Nominal Overall Diameter
(mm)

App. Weight
(Kg/Km)

0.5

1/0.8

0.5
5.5
7.7

9.5

1.1

11.7

467

1.3

1/1.29

0.6
6.9
9.1

10.9

1.1

13.1

563

0.5 sqmm (1/0.8mm)

No. of Pairs

Nominal Diameter Laid Up Pairs
(mm)

Nominal Diameter Collective Screen
(mm)
RT of Inner Bedding
(mm)
Diameter over Inner Bedding
(mm)

RT of Lead Alloy Sheath
(mm)

Diameter over Lead Alloy Sheath
(mm)

2

7.5

8.5
0.9
10.3

1.1

12.5

5
10.1
11.1
1.2
13.5
1.1
14.7
10
14.9
15.9
1.2
18.3
1.2
20.7
20
19.9
20.9
1.3
23.5
1.4
26.3
30
23.9
24.9
1.5
27.9
1.5
30.9

50

31.1

32.1
2.0
36.1

1.8

39.7


No. of Pairs

RT of Outer Bedding
(mm)

Diameter of Outer Bedding
(mm)
Diameter of Armour Wire
(mm)
Diameter over Armour
(mm)
RT of Outer Sheath
(mm)

Nominal Overall Diameter
(mm)

Weight
(Kg/Km)

2

0.8

14.1
1.25
16.6
1.5

19.6

1140

5
0.8
17.3
1.25
19.8
1.6
23.0
1450
10
1.0
22.7
1.6
25.9
1.7
29.3
2300
20
1.2
28.7
2.0
32.7
1.9
36.5
3580
30
1.2
33.3
2.0
37.3
2.0
41.3
4470

50

1.4

42.5
2.5
47.5
2.3

52.1

6780

Operating Temperature: Max 105°C, Min -30°C, Min bending 0°C

Min bending radius: 12 X Overall Diameter

Conductor Dimensions

Size & Stranding: 0.5 sqmm (1/0.8mm)